HAR §11-99-56
HAR §11-99-56. requested by a resident
Cite as Haw. Code R. § 11-99-56
(E)
An effective means of signaling staff
from the resident's bedside.
(f)
Ramps shall be designed to permit use by
residents in wheelchairs. Ramps shall meet the
requirements of the Uniform Building Code 1979 edition
and its revisions.
(g)
Floors and walls
(1)
Floors shall be of slip-resistant materials
which does not retain odors and is flush at
doorways.
(2)
Walls, floors and ceilings of rooms used by
residents shall be made of materials which
shall permit washing, cleaning, and painting.
(b)
Windows and lighting.
(1)
Each bedroom shall have at least one outside
window.
(2)
A bedroom shall have an aggregate window area
of not less than one-tenth of the gross floor
area.
(3)
Residents' rooms shall have adequate
artificial light.
(4)
There shall be night lighting in residents'
rooms, toilets, and service areas.
(5)
In rooms containing wheelchair residents, at
least one window shall be low enough to permit
outdoor viewing by the wheelchair-bound
resident.
(i)
Where appropriate, screening of doors and
windows shall be provided, using screening having
sixteen meshes per inch.
(j)
Doors
(1)
Sliding doors or folding doors shall not be
used as exit doors, and if used in other
areas, shall be of light material and easy to
handle.
(2)
Double acting doors shall be provided with
vision panels of sufficient height to permit
use by walkers as well as wheelchair riders.
(k)
Corridors
(1)
The minimum clear width of a corridor shall be
forty-four inches except that corridors
serving one or more nonambulatory or
semi-ambulatory residents shall be not less
than eight feet in width.
§11-99-56
(2)
Stationary handrails shall be installed along
both sides of corridors.
(l)
Storage space
(1)
Locked space shall be provided for janitor's
supplies and equipment.
(2)
Space, conveniently located, for other
equipment shall be provided.
(m)
Water supply. The water supply shall be in
accordance with the provisions of chapter 340-E, HRS.
(n)
Ventilation. Chapter 11-39 Administrative
Rules, entitled "Air conditioning and Ventilating",
shall be followed.
(o)
Additions and alterations or repairs to
existing buildings.
(1)
Where the structure was in use for this type
occupancy prior to the effective date of these
rules, the director, with discretion, may
waive or modify any portion of the standard
provided such exceptions do not create a
hazard to residents, personnel or public.
(2)
This section does not prohibit the use of
equivalent alternate space utilizations, new
concepts of plan designs and material or
systems if written approval of such
alternatives is granted by the department.
(3)
Drawings and specifications for all new
construction or additions, alterations, or
repairs, to existing buildings subject to this
chapter shall be submitted to the department
for review and a certificate of need where
applicable.
(4)
Construction shall not commence prior to the
department's approval of construction drawings
and specifications.
(5)
The department shall review such submittals
and advise the applicant in writing of its
determination.
(6)
The department may make written
recommendations to the applicant for its
consideration but the recommendations shall
not be considered mandatory.
(7)
Unless construction is commenced within one
year of the approval of final construction
drawings and specifications together with
§11-99-56
their application shall be resubmitted for
review and approval.
(8)
Minor alterations which do not affect
structural integrity, fire safety, or change
functional operation, or which do not increase
beds or services over that for which the
facility is licensed may be submitted by free
hand drawings or by more conventional drawings
and specifications.
(9)
Maintenance and repair routinely performed by
the facility do not require review or approval
by the department.
(10) Facilities shall be constructed and maintained
in accordance with provisions of state and
county zoning, building, fire safety and
sanitation codes and laws applicable in the
state.
[Eff. April 29, 1985] (Auth: HRS §§321-9,
321-10, 321-11, 333-53) (Imp: HRS §§333-51,
333-53)