HAR §12-229-17

HAR §12-229-17. Records

Last amended: 2021Length: 671 wordsOfficial source

Cite as Haw. Code R. § 12-229-17

Records shall be maintained by the elevator inspection branch of the department of labor and industrial relations for the purpose of preserving reports of inspections, witnessing of test and accident investigations, correspondence, prints, and memoranda for all objects inspected pursuant to this chapter. These records shall be maintained for a period of not less than five years for amusement rides, elevators, and kindred equipment." [Eff and comp 6/30/14; comp 11/10/16; comp 2/15/19; comp 1/31/21; comp JUN142026 ] (Auth: HRS §397-4) (Imp: HRS §397-4) 229-34 EXHIBIT A ELEVATOR AND KINDRED EQUIPMENT INSTALLATION AND ALTERATION FEES January 1, 2025 Alterations*: Involving only the replacement of a single major component (such as a car door operator, valve, a jack or a cylinder) Involving only cosmetic changes (such as car interior modernizations) Involving two or more major components and/or subsystems: 1-3 floors 4-9 floors 10-19 floors 20-29 floors 30-39 floors 40 or more floors Escalator alteration New Installations* Dumbwaiter or material lift Escalator, moving walk, or moving ramp Platform lifts or stairway chairlifts Elevator: 1-3 floors 4-9 floors 10-19 floors 20-29 floors 30-39 floors 40 or more floors Personnel hoists Temporary use permits (construction car) Additional inspections: Normal workday, up to two hours Normal workday, more than two hours Overtime hours, up to two hours Overtime hours, more than two hours $300 $500 $900 $1,000 $1,100 $1,150 $1,250 $1,400 $750 $750 $750 $750 $900 $1,000 $1,100 $1,150 $1,250 $1,400 $650 $650 $500/day $1,000/day $1,000/day $2,000/day For elevators which have considerable rise but few openings, such as observation or deep-well elevators, each ten feet of vertical rise shall be considered one floor for the purpose of determining installation or alteration permit fees. 229-35 EXHIBIT B ELEVATOR AND KINDRED EQUIPMENT INSPECTION FEES January 1, 2025 Permit and Renewal Inspection Fees1: Dumbwaiter or material lift Escalator, moving walk, or moving ramp Platform Lift or Stairway Chairlift Hydraulic elevator - holed Hydraulic elevator - holeless Hydraulic elevator - roped holeless Traction elevators: 1-3 floors 4-9 floors 10-19 floors 20-29 floors 30-39 floors 40 or more floors Personnel hoist Temporary Use Permit (construction car) Safety, load or internal test (witness fees): Category 3 test Category 3 test with safety overspeed valve Category 3/5 test for roped hydraulic Category 5 test Category 5 with counterweight test Escalator, internal $225 $325 $325 $400 $400 $475 $375 $400 $450 $525 $625 $725 $450 $450 $475 $550 $625 $625 $775 $625 For elevators which have considerable rise but few openings, such as observation or deep-well elevators, each ten feet of vertical rise shall be considered one floor for the purpose of determining permit renewal inspection fees. Permit renewal and witness fees are per inspection, which may constitute one day or part of the day. If the inspector is required to return on another day or at another time on the same day, additional fees shall be assessed at the rate of $500 per day for up to two hours and $1,000 per day for more than two hours. Fees for overtime hours shall be $1,000 per day for up to two hours and $2,000 per day for more than two hours. 229-36 EXHIBIT C INSPECTION AND TEST INTERVALS (IN MONTHS) January 1, 2017 Equipment Type Electric elevators Hydraulic elevators Roped-hydraulic Elevators Escalators and moving walks rii Dumbwaiters Material lifts Platform lifts and stairway chairlifts Inclined elevators Screw-column elevators Roof-top elevators Construction cars Personnel Amusement hoists r 21 rides Permit Renewal 12 12 12 12 12 12 12 12 12 12 3 3 6 Category Category 3 5 N/A 60 36 N/A 36 60 36 N/A 36 60 36 60 N/A N/A 36 60 36 60 36 60 36 60 N/A N/A N/A N/A 1 Internal inspections of escalators and moving walks shall be performed at intervals of 36 months. 2 Personnel hoists shall be load tested at intervals of 3 months. Where an equipment is listed under both Category 3 of 36 months and Category 5 of 60 months, a combined Category 3 and Category 5 testing may be conducted every 5 years. 229-37
HAR §12-229-17: HAR §12-229-17. Records | Justis AI