HAR §12-230.1-3
HAR §12-230.1-3. Engineers A17
Cite as Haw. Code R. § 12-230.1-3
1 is amended to read: "The data
plate shall be in plain view and securely
attached to the controller door. An additional
data plate shall be installed in the vicinity of
the top key operated starting switch on the
exterior of escalators and moving walks.".
(b)
A stairway or ladder shall be provided at all
personnel points of access where there is a break in
elevation of eight (8) inches (200 millimeters) or more
and when no ramp or runway is provided.
(c)
International Building Code, 2012 edition,
chapter 30, Elevators and Conveying Systems, is adopted by
reference and made a part of this chapter, and shall apply
to all new elevators and kindred equipment.
(d)
International Code Council A117.1-2009,
Accessible and Usable Buildings and Facilities, sections
407, 410, and related portions of sections 106, 302, 308,
309, 703, and 705 are adopted by reference and made a part
of this chapter, and shall apply to all new installations.
(e)
Chapter 21 of the National Fire Protection
Association 72 National Fire Alarm and Signaling Code,
2010 edition, and its related annexes and provisions are
adopted by reference and made a part of this chapter, and
shall apply to all new elevators.
(f)
Article 620 of the National Fire Protection
Association 70, National Electric Code, 2011 edition, and
its related provisions are adopted by reference and made a
part of this chapter, and shall apply to all new
elevators.
(g)
Paragraph 8.15.5, of National Fire Protection
Association 13, Standard for the Installation of Sprinkler
Systems, 2010 edition, is adopted by reference and made a
part of this chapter, and shall apply to all new elevators
and escalators. The annexes A.8.15.5.1 to A.8.15.5.4,
D.1.1.9.2, D.1.1.10.2, D.2.23.2.2, and D.2.24.2.2, are
explanatory and informational only.
(h)
In each machine room, control room, machinery
space, control space, and hoistway pit, there shall be
provided at least one 125-volt, single phase, 15- or 20-
ampere ground fault circuit interrupter (GFCI) duplex
receptacle.
12-230.1-4
§12-230.1-4
(i)
All lamps utilized for illumination in machine
room/space, control room/space, hoistway and pit, shall be
externally guarded to prevent accidental breakage.
(j)
Section 2.27.8 (switch keys) of American Society
of Mechanical Engineers A17.1 is amended to read: "The key
switches required by 2.27.2 through 2.27.5 for all
elevators in a building shall be operable by the "FEO-Kl"
key. The keys shall be Group 3 Security (see 8.1). A
separate key shall be provided for each switch. These keys
shall be kept inside the firefighter's lockbox. The
firefighter's lockbox shall be located immediately
adjacent to the firefighter's emergency recall key switch,
at an approximate height of six (6) feet above the floor.
Access to the firefighter's lockbox shall only be the
standardized key (#25460) for Hawaii, as required by the
Authority Having Jurisdiction (AHJ). The firefighter's
emergency recall key switch shall be located six (6) feet
above the floor on the left-hand side of the elevator wall
when facing the elevator and six (6) feet above the floor
on the left-hand side of the left elevator when facing the
elevators for a group of elevators. The key for the
firefighter's emergency recall switch shall be of a
tubular, 7-pin, style 137 construction and shall have a
bitting code of 6143521 starting at the tab sequenced
clockwise as viewed from the barrel end of the key. The
key shall be coded "FEO-Kl". The possession of the "FEO-
Kl" key shall be limited to elevator personnel, emergency
personnel, elevator equipment manufacturers, and
authorized personnel during checking of the Firefighter's
Emergency Operation (see 8.1 and 8.6.11.1) "
[Eff
6/30/14; am and comp 11/10/16, am and
~~;~_ffS f' 5 2019
]
(Auth:
HRS §397-4)
(Imp:
HRS
§12-230.1-4
Requirements for existing e1evators,
esca1ators, dumbwaiters, moving wa1ks, and materia1 1ifts
and dumbwaiters with automatic transfer devices.
(a)
All
existing elevators, escalators, moving walks, and
dumbwaiters and material lifts without automatic transfer
devices shall comply with the code in effect at the time
12-230.1-5
. 13 32 3
14~
§12-230.1-4
of installation or alteration as illustrated in Exhibit A,
titled "Existing Elevator and Kindred Equipment Code
Application Dates", dated January 1, 2017, which is made a
part of this chapter and located at the end of this
chapter, provided that for those years where the Hawaii
Registration number (HAW) did not specify code year, the
code version of the American Society of Mechanical
Engineers A17.1 in effect at the time of installation or
alteration shall apply. The director shall have the
discretion to apply a specific code to any elevator and
related system if the applicable code cannot be readily
ascertained. If the installation or alteration permit was
issued after 1997, then the elevator or kindred equipment
shall comply with American Society of Mechanical Engineers
A17.3-2011, which is adopted by reference and made a part
of this chapter.
(b)
The following provisions of American Society of
Mechanical Engineers A17.1-2010 are adopted by reference
and shall apply to existing elevators and kindred
equipment as stated:
(1)
Part 1, General, shall apply to all existing
elevators, escalators, moving walks, and
dumbwaiters, and material lifts;
(2)
Section 5.10, Elevators Used for Construction,
shall apply to all existing elevators used for
construction;
(3)
Section 8.1, Security, shall apply to all
existing elevators, escalators, and moving
walks;
(4)
Section 8.6, Maintenance, Repair, Replacement
and Testing, shall apply to all existing
elevators, escalators and moving walks, and
dumbwaiters and material lifts with automatic
transfer devices with the following amendment:
Section 8.6.1.2.l(c) of the American Society of
Mechanical Engineers A17.1 shall not apply;
(5)
Section 8.7, Alterations, shall apply to all
existing elevators, escalators, moving walks,
and material lifts and dumbwaiters with
automatic transfer devices;
(6)
Section 8.8, Welding, shall apply to all
existing elevators, escalators, moving walks,
12-230.1-6
§12-230.1-4
and material lifts and dumbwaiters with
automatic transfer devices;
(7)
Section 8.9, Code Data Plate, shall apply to all
existing elevators, escalators, moving walks,
and material lifts and dumbwaiters with
automatic transfer devices, except section 8.9.2
is amended to read: "The data plate shall be in
plain view and securely attached to the
controller door.
An additional data plate shall
be installed in the vicinity of the top key
operated starting switch on the exterior of
escalators and moving walks.";
(8)
Section 8.10, Acceptance Inspections and Tests,
shall apply to all existing elevators,
escalators, moving walks, and material lifts and
dumbwaiters with automatic transfer devices; and
(9)
Section 8.11, Flood Resistances, shall apply to
all existing elevators, escalators, moving
walks, and material lifts and dumbwaiters with
automatic transfer devices.
(c)
Chapter 12-240 shall apply to all elevators
where the installation or alteration application was
received by the department after December 6, 1990.
(d)
American Society of Mechanical Engineers 17.6-
2010 shall apply to existing elevators with other types of
suspension means and steel cables less than three-eighths
of an inch in diameter.
[Eff 6/30/14; am and comp
11/10/16; am and comp
FE8 f'5 2019
]
(Auth:
HRS §397-
4)
(Imp:
HRS §397-4)
12-230.1-7
EXHIBIT A
EXISTING ELEVATOR AND KINDRED EQUIPMENT
CODE APPLICATION DATES
January 1, 2017
YEAR
CODE/RULE
A17.1 REFERENCE YEAR
Implemented
1958
HAR Chapter 22
No year specified,
Applicable ANSI Edition
1955
1964
HAR Chapter 22
1960
1969
HAR Chapter 22
1965
1982
HAR Chapter 230
1981
1990
HAR Chapter 230
1987
1993
HAR Chapter 230
1990
1998
HAR Chapter 230
1996
2000
HAR Chapter 230
1996
2014
HAR Chapter
2010
230.1
) 32 3