HAR §12-230.1-3

HAR §12-230.1-3. Engineers A17

Last amended: 2019Length: 1,230 wordsOfficial source

Cite as Haw. Code R. § 12-230.1-3

1 is amended to read: "The data plate shall be in plain view and securely attached to the controller door. An additional data plate shall be installed in the vicinity of the top key operated starting switch on the exterior of escalators and moving walks.". (b) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of eight (8) inches (200 millimeters) or more and when no ramp or runway is provided. (c) International Building Code, 2012 edition, chapter 30, Elevators and Conveying Systems, is adopted by reference and made a part of this chapter, and shall apply to all new elevators and kindred equipment. (d) International Code Council A117.1-2009, Accessible and Usable Buildings and Facilities, sections 407, 410, and related portions of sections 106, 302, 308, 309, 703, and 705 are adopted by reference and made a part of this chapter, and shall apply to all new installations. (e) Chapter 21 of the National Fire Protection Association 72 National Fire Alarm and Signaling Code, 2010 edition, and its related annexes and provisions are adopted by reference and made a part of this chapter, and shall apply to all new elevators. (f) Article 620 of the National Fire Protection Association 70, National Electric Code, 2011 edition, and its related provisions are adopted by reference and made a part of this chapter, and shall apply to all new elevators. (g) Paragraph 8.15.5, of National Fire Protection Association 13, Standard for the Installation of Sprinkler Systems, 2010 edition, is adopted by reference and made a part of this chapter, and shall apply to all new elevators and escalators. The annexes A.8.15.5.1 to A.8.15.5.4, D.1.1.9.2, D.1.1.10.2, D.2.23.2.2, and D.2.24.2.2, are explanatory and informational only. (h) In each machine room, control room, machinery space, control space, and hoistway pit, there shall be provided at least one 125-volt, single phase, 15- or 20- ampere ground fault circuit interrupter (GFCI) duplex receptacle. 12-230.1-4 §12-230.1-4 (i) All lamps utilized for illumination in machine room/space, control room/space, hoistway and pit, shall be externally guarded to prevent accidental breakage. (j) Section 2.27.8 (switch keys) of American Society of Mechanical Engineers A17.1 is amended to read: "The key switches required by 2.27.2 through 2.27.5 for all elevators in a building shall be operable by the "FEO-Kl" key. The keys shall be Group 3 Security (see 8.1). A separate key shall be provided for each switch. These keys shall be kept inside the firefighter's lockbox. The firefighter's lockbox shall be located immediately adjacent to the firefighter's emergency recall key switch, at an approximate height of six (6) feet above the floor. Access to the firefighter's lockbox shall only be the standardized key (#25460) for Hawaii, as required by the Authority Having Jurisdiction (AHJ). The firefighter's emergency recall key switch shall be located six (6) feet above the floor on the left-hand side of the elevator wall when facing the elevator and six (6) feet above the floor on the left-hand side of the left elevator when facing the elevators for a group of elevators. The key for the firefighter's emergency recall switch shall be of a tubular, 7-pin, style 137 construction and shall have a bitting code of 6143521 starting at the tab sequenced clockwise as viewed from the barrel end of the key. The key shall be coded "FEO-Kl". The possession of the "FEO- Kl" key shall be limited to elevator personnel, emergency personnel, elevator equipment manufacturers, and authorized personnel during checking of the Firefighter's Emergency Operation (see 8.1 and 8.6.11.1) " [Eff 6/30/14; am and comp 11/10/16, am and ~~;~_ffS f' 5 2019 ] (Auth: HRS §397-4) (Imp: HRS §12-230.1-4 Requirements for existing e1evators, esca1ators, dumbwaiters, moving wa1ks, and materia1 1ifts and dumbwaiters with automatic transfer devices. (a) All existing elevators, escalators, moving walks, and dumbwaiters and material lifts without automatic transfer devices shall comply with the code in effect at the time 12-230.1-5 . 13 32 3 14~ §12-230.1-4 of installation or alteration as illustrated in Exhibit A, titled "Existing Elevator and Kindred Equipment Code Application Dates", dated January 1, 2017, which is made a part of this chapter and located at the end of this chapter, provided that for those years where the Hawaii Registration number (HAW) did not specify code year, the code version of the American Society of Mechanical Engineers A17.1 in effect at the time of installation or alteration shall apply. The director shall have the discretion to apply a specific code to any elevator and related system if the applicable code cannot be readily ascertained. If the installation or alteration permit was issued after 1997, then the elevator or kindred equipment shall comply with American Society of Mechanical Engineers A17.3-2011, which is adopted by reference and made a part of this chapter. (b) The following provisions of American Society of Mechanical Engineers A17.1-2010 are adopted by reference and shall apply to existing elevators and kindred equipment as stated: (1) Part 1, General, shall apply to all existing elevators, escalators, moving walks, and dumbwaiters, and material lifts; (2) Section 5.10, Elevators Used for Construction, shall apply to all existing elevators used for construction; (3) Section 8.1, Security, shall apply to all existing elevators, escalators, and moving walks; (4) Section 8.6, Maintenance, Repair, Replacement and Testing, shall apply to all existing elevators, escalators and moving walks, and dumbwaiters and material lifts with automatic transfer devices with the following amendment: Section 8.6.1.2.l(c) of the American Society of Mechanical Engineers A17.1 shall not apply; (5) Section 8.7, Alterations, shall apply to all existing elevators, escalators, moving walks, and material lifts and dumbwaiters with automatic transfer devices; (6) Section 8.8, Welding, shall apply to all existing elevators, escalators, moving walks, 12-230.1-6 §12-230.1-4 and material lifts and dumbwaiters with automatic transfer devices; (7) Section 8.9, Code Data Plate, shall apply to all existing elevators, escalators, moving walks, and material lifts and dumbwaiters with automatic transfer devices, except section 8.9.2 is amended to read: "The data plate shall be in plain view and securely attached to the controller door. An additional data plate shall be installed in the vicinity of the top key operated starting switch on the exterior of escalators and moving walks."; (8) Section 8.10, Acceptance Inspections and Tests, shall apply to all existing elevators, escalators, moving walks, and material lifts and dumbwaiters with automatic transfer devices; and (9) Section 8.11, Flood Resistances, shall apply to all existing elevators, escalators, moving walks, and material lifts and dumbwaiters with automatic transfer devices. (c) Chapter 12-240 shall apply to all elevators where the installation or alteration application was received by the department after December 6, 1990. (d) American Society of Mechanical Engineers 17.6- 2010 shall apply to existing elevators with other types of suspension means and steel cables less than three-eighths of an inch in diameter. [Eff 6/30/14; am and comp 11/10/16; am and comp FE8 f'5 2019 ] (Auth: HRS §397- 4) (Imp: HRS §397-4) 12-230.1-7 EXHIBIT A EXISTING ELEVATOR AND KINDRED EQUIPMENT CODE APPLICATION DATES January 1, 2017 YEAR CODE/RULE A17.1 REFERENCE YEAR Implemented 1958 HAR Chapter 22 No year specified, Applicable ANSI Edition 1955 1964 HAR Chapter 22 1960 1969 HAR Chapter 22 1965 1982 HAR Chapter 230 1981 1990 HAR Chapter 230 1987 1993 HAR Chapter 230 1990 1998 HAR Chapter 230 1996 2000 HAR Chapter 230 1996 2014 HAR Chapter 2010 230.1 ) 32 3
HAR §12-230.1-3: HAR §12-230.1-3. Engineers A17 | Justis AI