HAR §12-240-12
HAR §12-240-12. Car controls
Length: 435 wordsOfficial source
Cite as Haw. Code R. § 12-240-12
Elevator control
panels shall have the following features:
(1)
Buttons. All control buttons shall be at
least three fourths (3/4) inch or nineteen
(19) millimeters in their smallest dimension.
They may be raised or flush;
(2)
Tactile and visual control indicators. All
control buttons shall be designated by
raised standard alphabet characters for
letters, Arabic characters for numerals, or
standard symbols as shown in Figure 240-
4(a), titled "Car Controls", dated December
6, 1990, which is made a part of this
chapter, and located at the end of this
chapter, and as required in ANSI Ai7.1-
1989. Raised characters and symbols shall
comply with ANSI All7.1-1986 Rule 4.30. The
call button for the main entry floor shall
be designated by a raised star at the left
of the floor designation as shown in Figure
240-4 (a), titled "Car Controls", dated
December 6, 1990, which is made a part of
this chapter, and located at the end of
this chapter. All raised designations for
control buttons shall be placed immediately
to the left of the button to which they
apply. Applied plates, permanently
attached, are an acceptable means to
provide raised control designations. Floor
12-240-6
J 32} I ,WAIi
§12-240-13
buttons shall be provided with visual
indicators to show when each call is
registered. The visual indicators shall be
extinguished when each call is answered;
(3)
Height. All floor buttons shall be no higher
than fifty-four (54) inches or 1220
millimeters, above the finish floor for side
approach and forty-eight (48) inches for
front approach. Emergency controls,
including the emergency alarm and emergency
stop, shall be grouped at the bottom of the
panel and shall have their centerlines no
less than thirty-five (35) inches
or 890
millimeters above the floor as shown in
Figures 240-4(a) and (b), entitled "Car
Controls", dated December 6, 1990, which is
made a part of this chapter, and located at
the end of this chapter. The emergency
alarm bell shall be operable under normal
power as well as for a minimum of one (1)
hour on auxiliary power in the event of the
loss of normal power; and
(4)
Location. Controls shall be located on a front
wall if cars have center opening doors, and at
the side wall or at the front wall next to the
door if cars have side opening doors as shown
in Figures 240-4(c) and (d), entitled "Car
Controls", dated December 6, 1990, which is
made a part of this chapter, and located at
the end of this chaptertb f&ff 12/6/90; am
11/5/93; am and comp
F~ '!> 2019
]
(Auth:
HRS §397-4)
(Imp:
HRS §397-4)