HAR §12-240-7
HAR §12-240-7. Door and signal timing for hall calls
Cite as Haw. Code R. § 12-240-7
The minimum acceptable time from notification that a car
is answering a call until the doors of that car start to
close shall be calculated from the following equation:
T=
D
1.5 ft./s
or T = D
455 mm/s
12-240-4
13323 .4.
§12-240-10
where T = total time in seconds and D = distance (in feet
or millimeters) from a point in the lobby or corridor
sixty (60) inches or 1525 millimeters directly in front of
the farthest call button controlling that car to the
centerline of its hoistway door as shown in Figure 240-2,
titled "Graph of Timing Equation", dated December 6,
1990, which is made a part of this chapter, and located
at the end of this chapter. For cars with in-car
lanterns, T begins when the lantern is visible from the
vicinity of hall call buttons and an audible signal is
sounded. The minimum acceptable notification time shall be
five (5) seconds.
[Eff 12/6/90; am and
comp
FEb f' 5 2019
§397-4)
.. ~
]
(Auth:
HRS §397-4)
(Imp:
HRS