HAR §13-183-80
HAR §13-183-80. Well operation and maintenance
Cite as Haw. Code R. § 13-183-80
(a) All wells
and their appurtenances such as well head, separators, pumps,
mufflers, scrubbers, manifolds, valves, and pipelines shall be
operated and maintained by the operator in good working condition
in order to prevent unacceptable pollution, waste and the loss of
or damage to life, health, property, natural resources, and
environment. The well head and appurtenances of all wells shall
meet a test pressure of at least one and a half times the
calculated or known pressure of the geothermal reservoir tapped
or to be tapped by the well.
(b)
Periodic corrosion surveillance of any well and
appurtenances may be conducted by the chairperson or authorized
representative and any leakage, waste, or hazard shall be
promptly corrected by the operator.
(c)
The operator of any well shall notify the chairperson
of any blowout, break, leak, or spill of any well or appurtenant
facilities. The notification to the chairperson shall consist of
a written report submitted within ten days after discovery of the
incident.
(d)
The chairperson shall notify the operator of any well
not being operated or maintained in accordance with these rules
to take whatever steps may be necessary to remedy the defect at
the operator's expense within the period of time specified in the
notice. If the operator fails to comply with the notice and
remedy the defect within the specified period, the chairperson
may do the work as maybe necessary to plug and abandon the well
or put it in proper condition at the expense of the operator or
the surety and the chairperson may take necessary action to
enforce the penalty provided in these rules. [Eff. JUN 22 1981]
(Auth: HRS §182-14) (Imp: HRS §182-14)
Subchapter 11, Drilling; Abandonment of Wells