HAR §13-183-83
HAR §13-183-83. Cementing requirements
Cite as Haw. Code R. § 13-183-83
(a) Cement used to
plug any well, except that cement or concrete used for surface
plugging, shall be placed in the hole by pumping through drill
pipe or tubing. The cement shall contain a high temperature
resistant admix unless this requirement is waived by the
chairperson the particular circumstances existing in that well or
47
area. All open annuli shall be filled solid with cement to the
surface.
(b)
One hundred lineal feet of cement shall be placed
straddling the bottom of the conductor pipe and at the shoes of
all casings.
(c)
Cement shall be placed solidly across geothermal zones
and extending one hundred lineal feet above and below the zones,
whether in uncased or cased (perforated) hole, except as follows:
(1)
One hundred lineal feet of cement shall be placed
straddling casing stubs and laps. If unable to enter
casing stubs or laps, one hundred lineal feet of cement
shall be placed above the top of the stubs or laps.
(2)
If casing is collapsed, etc., cement shall be placed
solidly in geothermal zones or perforated sections of
casing and extending one hundred lineal feet above the
zone or perforated section by squeezing with a retainer
or braden head.
(d)
Fifty lineal feet of cement shall be placed above the
top of casing liners.
(e)
A surface plug consisting of a minimum of fifty lineal
feet of neat cement or ready mix concrete shall be placed below
the surface of the well.
(f)
Where a well has been drilled with air, a bridge plug
may be placed at the deepest cemented casing shoe and the bridge
plug shall be capped with a minimum of two hundred lineal feet of
cement. [Eff. JUN 22 1981] (Auth: HRS §182-14) (Imp: HRS
§§178-3, 182-14)
Subchapter 12. Drilling; Records and Reports of Wells