HAR §15-23-63
HAR §15-23-63. Heights
Cite as Haw. Code R. § 15-23-63
(a) No portion of any
building or other structure located within any land
use zone shall exceed the height set forth in Exhibit
3, entitled "Maximum Height and Density Plan", dated
September 2005, and attached at the end of this
chapter.
(b) The height of any structure shall be
measured from ground elevation, except where finish
grade is higher than ground elevation in order to meet
city construction standards for driveways, roadways,
drainage, sewerage and other infrastructure
requirements.
(c) The following building elements or features
and associated screening shall be exempt from height
limits subject to the following restrictions:
(1) Necessary utilitarian features including:
stairwell enclosures, safety railings,
§15-23-64
23-41
ventilators, and skylights; decorative or
recreational features, including rooftop
gardens, planter boxes, flag poles, spires,
parapet walls or ornamental cornices; roof-
mounted mast, whip and dish antennae; and
energy-saving devices, including heat pumps
and solar collectors, may exceed the height
limit by not more than twelve feet; and
(2) Vent pipes, fans, roof access stairwells,
and structures housing rooftop machinery,
such as elevators and air-conditioning, and
chimneys, may exceed the height limit by not
more than eighteen feet.
(d) Miscellaneous building elements may exceed
the height limit subject to the zoning adjustment
process specified in section 15-23-21.
(e) Auditoriums, amphitheaters, and performing
arts centers may exceed the height limit as approved
by the executive director.
(f) Rooftop features which principally house
elevator machinery and air-conditioning equipment may
extend above the governing height limit for structures
subject to the zoning adjustment provision set forth
in section 15-23-21 and the following conditions:
(1) If the elevator cab opens on the roof,
machinery may not be placed above the
elevator housing;
(2) The highest point of the roofing treatment
shall not exceed five feet above the highest
point of equipment structures; and
(3) Areas proposed to be covered by the rooftop
feature will not be counted as floor area,
provided they are used only for the housing
of rooftop machinery. [Eff 2/24/90; am and
comp 10/10/98; comp 2/2/02; am and
comp 12/9/02; am and comp 11/3/05] (Auth:
HRS §§206E-4, 206E-5, 206E-7) (Imp: HRS
§§206E-4, 206E-5, 206E-7)