32 Ill. Adm. Code 335.7040
Accountability and Security of Brachytherapy Sources
Section 335
Section 335.7040
Accountability and Security of Brachytherapy Sources
a) A licensee shall maintain security and accountability at all
times for all brachytherapy sources in storage or use.
b) As soon as possible after removing sources from a patient or a
human research subject, a licensee shall return brachytherapy sources to a
secure storage area.
c) A licensee shall maintain a record of brachytherapy source
accountability required by this Section for 5 years. The record must include:
1) For
temporary implants:
A) The
number and activity of sources removed from storage, the time and date they
were removed from storage, the name of the individual who removed them from
storage and the location of use; and
B) The
number and activity of sources returned to storage, the time and date they were
returned to storage and the name of the individual who returned them to
storage.
2) For
permanent implants:
A) The
number and activity of sources removed from storage, the date they were removed
from storage, and the name of the individual who removed them from storage;
B) The
number and activity of sources not implanted, the date they were returned to
storage and the name of the individual who returned them to storage; and
C) The
number and activity of sources permanently implanted in the patient or human
research subject.