32 Ill. Adm. Code 340.210
Occupational Dose Limits for Adults
Section 340
Section 340.210 Occupational
Dose Limits for Adults
a) The licensee or registrant shall control the occupational dose
to individual adults, except for planned special exposures pursuant to Section
340.260, to the following dose limits:
1) An annual limit, which is the more limiting of:
A) The total effective dose equivalent being equal to 0.05 Sv (5
rem); or
B) The sum of the deep dose equivalent and the committed dose
equivalent to any individual organ or tissue other than the lens of the eye
being equal to 0.5 Sv (50 rem).
2) The annual limits to the lens of the eye, to the skin and to
the extremities which are:
A) A lens dose equivalent of 0.15 Sv (15 rem); and
B) A shallow dose equivalent of 0.5 Sv (50 rem) to the skin or to
any extremity.
b) Doses received in excess of the annual limits, including doses
received during accidents, emergencies and planned special exposures, shall be
subtracted from the limits for planned special exposures that the individual
may receive during the current year and during the individual's lifetime (see
Section 340.260(e)).
c) When the external exposure is determined by measurement with
an external personal monitoring device, the deep dose equivalent shall be used
in place of the effective dose equivalent unless the effective dose equivalent
is determined by a dosimetry method approved by the Agency. The assigned deep
dose equivalent shall be for the portion of the body receiving the highest
exposure. The assigned shallow dose equivalent shall be the dose averaged over
the contiguous 10 square centimeters of skin receiving the highest dose.
AGENCY NOTE:
The deep dose equivalent, lens dose equivalent or shallow dose equivalent may
be assessed from surveys or other radiation measurements for the purpose of
demonstrating compliance with the occupational dose limits if the individual
monitoring device was not in the region of highest potential exposure or the
results of individual monitoring are unavailable.
d) The deep dose equivalent, lens dose equivalent and shallow
dose equivalent may be assessed from surveys or other radiation measurements
for the purpose of demonstrating compliance with the occupational dose limits,
if the individual monitoring device was not in the region of highest potential
exposure, or the results of individual monitoring are unavailable.
e) Derived air concentration (DAC) and annual limit on intake
(ALI) values are specified in table 1 of appendix B to 10 CFR 20, published at
72 Fed. Reg. 55922, October 1, 2007, exclusive of subsequent amendments or
editions, and may be used to determine the individual's dose (see Section
340.1160) and to demonstrate compliance with the occupational dose limits.
f) Notwithstanding the annual dose limits, the licensee shall
limit the soluble uranium intake by an individual to 10 milligrams in a week in
consideration of chemical toxicity (see footnote 3 of appendix B to 10 CFR 20, published
at 72 Fed. Reg. 55922, October 1, 2007, exclusive of subsequent amendments or
editions.)
g) The licensee or registrant shall reduce the dose that an
individual may be allowed to receive in the current year by the amount of
occupational dose received while employed by any other person during the
current year (see Section 340.250(a) and (d)).
AGENCY NOTE:
The purpose of this requirement is to ensure that no individual receives an annual
occupational dose in excess of the occupational dose limits set forth in this
Section.