32 Ill. Adm. Code 340.630
Control of Access to Very High Radiation Areas – Irradiators
Section 340
Section 340.630 Control of
Access to Very High Radiation Areas – Irradiators
a) This Section applies to licensees or registrants with sources
of radiation in irradiators that are not self-shielded. This Section does not
apply to sources of radiation that are used in teletherapy, in industrial
radiography or in completely self-shielded irradiators in which the source is
both stored and operated within the same radiation shielding barrier and, in
the designed configuration of the irradiator, is always physically inaccessible
to any individual and cannot create a radiation level of 5 Gy (500 rad) or more
in 1 hour at 1 meter in an area that is accessible to any individual.
b) Each area in which there may exist radiation levels in excess
of 5 Gy (500 rad) in 1 hour at 1 meter from a source of radiation that is used
to irradiate matter shall meet the following requirements:
1) Each entrance or access point shall be equipped with entry
control devices that:
A) Function automatically to prevent any individual from
inadvertently entering a very high radiation area;
B) Permit deliberate entry into the area only after a control
device is actuated that causes the radiation level within the area, from the
source of radiation, to be reduced below that at which it would be possible for
an individual to receive a deep dose equivalent in excess of 1 mSv (0.1 rem) in
1 hour; and
C) Prevent operation of the source of radiation if it would
produce radiation levels in the area that could result in a deep dose
equivalent to an individual in excess of 1 mSv (0.1 rem) in 1 hour.
2) Additional control devices shall be provided so that, upon
failure of the entry control devices to function as required by subsection
(b)(1) of this Section:
A) The radiation level within the area, from the source of
radiation, is reduced below that at which it would be possible for an
individual to receive a deep dose equivalent in excess of 1 mSv (0.1 rem) in 1
hour; and
B) Conspicuous visible and audible alarm signals are generated to
make an individual attempting to enter the area aware of the hazard. The alarm
signals shall be located so that at least one other authorized individual, who
is physically present, familiar with the activity, and prepared to render or
summon assistance, is made aware of the failure of the entry control devices.
3) The licensee or registrant shall provide control devices so
that, upon failure or removal of any physical radiation barriers, other than
the shielded storage container for sealed sources:
A) The radiation level from the source of radiation is reduced below
that at which it would be possible for an individual to receive a deep dose
equivalent in excess of 1 mSv (0.1 rem) in 1 hour; and
B) Conspicuous visible and audible alarm signals are generated to
make potentially affected individuals aware of the hazard and the licensee or
registrant or at least one other individual, who is familiar with the activity
and prepared to render or summon assistance, aware of the failure or removal of
the physical barrier.
4) When the shield for the stored sealed source is a liquid, the
licensee shall provide means to monitor the integrity of the shield and to
signal, automatically, loss of adequate shielding.
5) Physical radiation barriers that comprise permanent structural
components, such as walls, that have no credible probability of failure or
removal in ordinary circumstances need not meet the requirements of subsections
(b)(3) and (4) of this Section.
6) Each area shall be equipped with devices that will
automatically generate conspicuous visible and audible alarm signals to alert
personnel in the area before the source of radiation can be put into operation
and in time for any individual in the area to operate a clearly identified
control device, which must be installed in the area and that can prevent the
source of radiation from being put into operation.
7) Each area shall be controlled by use of devices and
administrative procedures that ensure that the area is cleared of personnel
prior to each use of the source of radiation.
8) Each area shall be checked by a radiation measurement to
ensure that, prior to the first individual's entry into the area after any use
of the source of radiation, the radiation level from the source of radiation in
the area is below that at which it would be possible for an individual to
receive a deep dose equivalent in excess of 1 mSv (0.1 rem) in 1 hour.
9) The entry control devices required in subsection (b)(1) of
this Section shall be tested for proper functioning (see Section 340.1190 of
this Part for recordkeeping requirements).
A) Testing shall be conducted prior to initial operation with the
source of radiation on any day, unless operations were continued uninterrupted
from the previous day;
B) Testing shall be conducted prior to resumption of operation of
the source of radiation after any unintentional interruption; and
C) The licensee or registrant shall submit and adhere to a
schedule for periodic tests of the entry control and warning systems.
10) The licensee or registrant shall not conduct operations,
other than those necessary to place the source of radiation in safe condition
or to effect repairs on controls, unless control devices are functioning
properly.
11) Entry and exit portals that are used in transporting matter
to and from the irradiation area, and that are not intended for use by
individuals, shall be controlled by such devices and administrative procedures
as are necessary to physically protect and warn against inadvertent entry by any
individual through these portals. Exit portals for irradiated matter shall be
equipped to detect and signal the presence of any loose sealed sources that are
carried toward such an exit and to automatically prevent loose sealed sources
from being carried out of the area.
c) Registrants, licensees or applicants for licenses for sources
of radiation that are within the purview of subsection (b) of this Section and that
will be used in a variety of positions or in locations (e.g., open fields or
forests) that make it impracticable to comply with certain requirements of
subsection (b) of this Section, such as those for the automatic control of
radiation levels, may apply to the Agency for approval of alternative safety
measures. Alternative safety measures shall provide personnel protection at
least equivalent to those specified in subsection (b) of this Section. At
least one of the alternative measures shall include an entry-preventing
interlock control based on a measurement of the radiation that ensures the
absence of high radiation levels before an individual can gain access to the
area where such sources of radiation are used.
d) The entry control devices required by subsections (b) and (c) of
this Section shall be established in such a way that no individual will be
prevented from leaving the area.