32 Ill. Adm. Code 340.730
Use of Individual Respiratory Protection Equipment
Section 340
Section 340.730 Use of
Individual Respiratory Protection Equipment
a) If the licensee assigns or permits the use of respiratory
protection equipment to limit the intake of radioactive material then:
1) Except as provided in subsection (a)(2), the licensee shall
use only respiratory protection equipment that is tested and certified by the
National Institute for Occupational Safety and Health (NIOSH).
2) The licensee may use equipment that has not been tested or
certified by NIOSH, or for which there is no schedule for testing or
certification, provided the Agency has approved an application for authorized
use of that equipment. The application shall include evidence that the material
and performance characteristics of the equipment are capable of providing the
proposed degree of protection under anticipated conditions of use. This shall
be demonstrated either by licensee testing or on the basis of reliable test
information.
3) The licensee shall implement and maintain a respiratory
protection program that includes:
A) Air
sampling sufficient to identify the potential hazard, permit proper equipment
selection, and estimate doses.
B) Surveys and bioassays,
as necessary, to evaluate actual intakes.
C) Testing
of respirators for operability (user seal check for face sealing devices and
functional check for others) immediately prior to each use.
D) Written procedures
regarding:
i) Monitoring,
including air sampling and bioassays;
ii) Supervision
and training of respirator users;
iii) Fit
testing;
iv) Respirator
selection;
v) Breathing
air quality;
vi) Inventory
and control;
vii) Storage,
issuance, maintenance, repair, testing, and quality assurance of respiratory protection
equipment;
viii) Recordkeeping;
and
ix) Limitations
on periods of respirator use and relief from respirator use.
E) Determination
by a physician that the individual user is medically fit to use respiratory
protection equipment:
i) Before
the initial fitting of a face sealing respirator;
ii) Before
the first field use of non-face sealing respirators; and
iii) Either
every 12 months thereafter or periodically at a frequency determined by a
physician.
F) Fit testing, with a fit factor > 10 times the APF for
negative pressure devices, and a fit factor > 500 for any positive pressure,
continuous flow, and pressure-demand devices, before the first field use of
tight fitting, face-sealing respirators and periodically thereafter at a
frequency not to exceed 1 year. Fit testing must be performed with the
facepiece operating in the negative pressure mode.
4) The licensee shall advise each respirator user that the user
may leave the area at any time for relief from respirator use in the event of
equipment malfunction, physical or psychological distress, procedural or
communication failure, significant deterioration of operating conditions, or
any other conditions that might require such relief.
5) The
licensee shall consider limitations appropriate to the type and mode of use.
When selecting respiratory devices the licensee shall provide for vision
correction, adequate communication, low temperature work environments, and the
concurrent use of other safety or radiological protection equipment. The licensee
shall use equipment in such a way as not to interfere with the proper operation
of the respirator.
6) Standby
rescue persons are required whenever one-piece atmosphere-supplying suits, or
any combination of supplied air respiratory protection device and personnel
protective equipment are used from which an unaided individual would have
difficulty extricating himself or herself. The standby persons shall be
equipped with respiratory protection devices or other apparatus appropriate for
the potential hazards. The standby rescue persons shall observe or otherwise
maintain continuous communication with the workers (visual, voice, signal line,
telephone, radio, or other suitable means), and be immediately available to
assist them in case of a failure of the air supply or for any other reason that
requires relief from distress. A sufficient number of standby rescue persons shall
be immediately available to assist all users of this type of equipment and to
provide effective emergency rescue if needed.
7) Atmosphere-supplying
respirators must be supplied with respirable air of grade D quality or better
as defined by the Compressed Gas Association in publication G-7.1,
"Commodity Specification for Air", 1997 and included in the
regulations of the Occupational Safety and Health Administration at 29 CFR
1910.134(i)(1)(ii)(A) through (E) (2019). Grade D quality air criteria include:
i) Oxygen content (v/v)
of 19.5-23.5%;
ii) Hydrocarbon
(condensed) content of 5 milligrams per cubic meter of air or less;
iii) Carbon monoxide (CO)
content of 10 ppm or less;
iv) Carbon dioxide content
of 1,000 ppm or less; and
v) Lack of noticeable
odor.
8) The
licensee shall ensure that no objects, materials, or substances, such as facial
hair, or any conditions that interfere with the face, facepiece seal, or valve
function, under the control of the respirator wearer, are present between the
skin of the respirator wearer's face and the sealing surface of a tight-fitting
respirator facepiece.
b) When estimating the dose to individuals from intake of
airborne radioactive materials, the concentration of radioactive material in
the air that is inhaled when respirators are worn is initially assumed to be
the ambient concentration in air without respiratory protection, divided by the
assigned protection factor. If the dose is later found to be greater than the
estimated dose, the corrected value shall be used; if the dose is later found
to be less than the estimated dose, the corrected value may be used.
Protection factors for respirators are specified in Appendix A to 10 CFR 20
(1999).
c) The licensee shall obtain authorization from the Agency before
using assigned protection factors in excess of those specified in Appendix A to
10 CFR 20 (1999). The Agency may authorize a licensee to use higher assigned protection
factors on receipt of an application that:
1) Describes the situation for which a need exists for higher
protection factors; and
2) Demonstrates that the respiratory protection equipment
provides these higher protection factors under the proposed conditions of use.
d) The Agency may impose restrictions in addition to the
provisions of this Section, Section 340.720, and Appendix A to 10 CFR 20 (1999)
in order to ensure the respiratory protection program of the licensee is
adequate to limit doses to individuals from intakes of airborne radioactive
materials consistent with maintaining total effective dose equivalent ALARA and
limit the extent to which a licensee may use respiratory protection equipment
instead of process or other engineering controls.