32 Ill. Adm. Code 340.830
Control of Volatiles and Gases
Section
340.830 Control of Volatiles and Gases
a) A licensee
who uses or stores radioactive volatile materials or gases shall do so with a
system that will keep airborne concentrations within the limits prescribed in
this Part.
b) The system shall either be directly vented to
the atmosphere through an air exhaust or provide for collection and decay or
disposal of the volatile material or gas in a shielded container.
c) A licensee
shall use or store radioactive gases only in rooms that are at negative
pressure compared to surrounding rooms or hallways.
d) A licensee shall post, at the areas of use and
storage, emergency procedures to be followed in the event of a gas spill.
e) In the event of evacuation because of a spill
or leak, the licensee shall use a radiation detection survey instrument upon
room re-entry to ensure radiation levels have returned to background levels.
f) A licensee shall check the operation of
reusable collection systems monthly and measure the ventilation rates available
in areas of use at intervals not to exceed 6 months. The licensee shall
maintain a record of these checks and measurements for 5 years. The record
shall include the model and serial number of the collection system, results of
all checks recommended by the manufacturer of the collection system, the
ventilation rates measured, the date of the checks and measurements, and the
identity of the individual who performed the checks and measurements.
g) Contaminated
charcoal trap filters, air handling systems, and respiratory equipment shall be
disposed of in accordance with this Part.