32 Ill. Adm. Code 346.670
Entering and Leaving the Radiation Room
Section 346.670 Entering and Leaving the Radiation Room
a) Upon
first entering the radiation room of a panoramic irradiator after an
irradiation, the irradiator operator shall use a survey meter to determine that
the source has returned to its fully shielded position. The operator shall
check the functioning of the survey meter with a radiation check source prior
to entry.
b) Before
exiting from and locking the door to the radiation room of a panoramic
irradiator prior to a planned irradiation, the irradiator operator shall:
1) Visually
inspect the entire radiation room to verify that no one else is in it; and
2) Activate
a control in the radiation room that permits the sources to be moved from the
shielded position only if the door to the radiation room is locked within a pre-set
time after setting the control.
c) During
a power failure, the area around the pool of an underwater irradiator may not
be entered without using an operable and calibrated radiation survey meter,
unless the over-the-pool monitor required by Section 346.290(b) is operating
with backup power.