32 Ill. Adm. Code 350.3030
Radiation Surveys and Survey Records
Section 350
Section 350.3030 Radiation
Surveys and Survey Records
a) No industrial radiographic operation shall be conducted unless
at least one calibrated and operable radiation survey instrument, as described
in Section 350.1040 of this Part, is available and used at each site where
radiographic exposures are made.
b) A survey with a radiation survey instrument shall be made
after each use of a radiographic exposure device to determine that the sealed
source has been returned to its shielded position. The entire circumference of
the radiographic exposure device shall be surveyed. If the radiographic
exposure device has a source guide tube, the survey shall also include the
source guide tube and any attached collimator.
c) A lock-out survey, in which all accessible surfaces of the
radiographic exposure device or source changer are surveyed with a radiation
survey instrument, shall be made to determine that each sealed source is in its
shielded position prior to securing the radiographic exposure device or source
changer as specified in Section 350.1020 of this Part.
d) A physical radiation survey shall be made after each
radiographic exposure using a radiation machine to determine that the machine
is "off".
e) Radiation surveys shall be performed in areas where industrial
radiography operations are to be performed and shall meet the following
requirements:
1) Before industrial radiographic operations begin, all radiation
areas and high radiation areas (as determined by calculated exposure rates) in
which radiographic operations are to be performed shall be posted in accordance
with Section 350.3020 of this Part. An area survey shall be performed during
the first radiographic exposure (i.e., with the sealed source in the exposed
position) to confirm that the requirements specified in Section 350.3020 of
this Part have been met and that doses to individual members of the public do
not exceed the limits specified in 32 Ill. Adm. Code 340.310(a).
2) The survey required in subsection (e)(1) of this Section shall
be repeated each time the exposure device is relocated or the exposed position
of the sealed source is changed.
3) The requirements specified in subsection (e)(2) of this
Section do not apply to repetitive industrial radiographic operations when the
conditions of exposure, including, but not limited to, the radiographic
exposure device, duration of exposure, source strength, pipe size and pipe
thickness, remain constant.
f) If a vehicle is to be used for storage of radioactive material,
a vehicle survey shall be performed after securing radioactive material in the
vehicle and before commencement of transport to ensure that doses to individual
members of the public do not exceed the limits specified in 32 Ill. Adm. Code
340.310(a) at the exterior surface of the vehicle.
g) Surveys shall be performed on storage containers to ensure
that doses to individual members of the public do not exceed the limits
specified in 32 Ill. Adm. Code 340.310(a). These surveys shall be performed
initially with the maximum amount of radioactive material present in the
storage location and thereafter at the time of the quarterly inventory and
whenever storage conditions change.
h) A survey meeting the requirements of subsection (b) of this
Section shall be performed on the radiographic exposure device and the source
changer after every sealed source exchange.
i) Records shall be kept of the surveys required by subsections
(c) through (h) of this Section. The records shall be maintained for
inspection by the Agency for 5 years after completion of the survey. If the
survey was used to determine an individual's exposure, however, the records of
the survey shall be maintained until the radioactive material license or
certificate of registration is terminated or until the Agency authorizes their
disposition, in writing, following a determination by the Agency that the
records contain inaccurate information that could result in an inaccurate
determination of an individual's exposure.