32 Ill. Adm. Code 351.1100
Inspection and Maintenance
Section 351
Section 351.1100 Inspection
and Maintenance
a) Each licensee or registrant shall conduct, at intervals not to
exceed6 months, a program of inspection and maintenance of source holders,
logging tools, source handling tools, storage containers, transport containers
and injection tools to assure proper labeling and physical condition. Records
of inspection and maintenance shall be maintained for a period of 2 years for
inspection by the Agency.
b) If any inspection conducted pursuant to subsection (a) of this
Section reveals damage to labeling or components that could result in release
of radioactive material into the environment, or loss of control of radioactive
material or that could otherwise create a risk of increase in radiation
exposure, the device shall be removed from service until repairs have been
made.
c) The repair, opening or modification of any sealed source shall
be performed only by persons specifically authorized to do so by the Agency,
the U.S. Nuclear Regulatory Commission, an Agreement State or a Licensing
State.