32 Ill. Adm. Code 351.430
Inspection, Maintenance, and Opening of a Sealed Source or Source Holder
Section 351.430 Inspection,
Maintenance, and Opening of a Sealed Source or Source Holder
a) Each licensee or registrant shall visually check source
holders, logging tools, and source handling tools for defects before each use
to ensure that the equipment is in good working condition and required labeling
is present. If defects are found, the equipment shall be removed from service
until repaired and a record must be made listing the date of the check, name of
the inspector, equipment involved, defects found, and repairs made. Records shall
be retained for 3 years after the defect is found.
b) Each licensee or registrant shall have a program for
semiannual visual inspection and routine maintenance of source holders, logging
tools, injection tools, source handling tools, storage containers, transport
containers, and uranium sinker bars to ensure that the required labeling is
legible and no physical damage is visible. If defects are found, the equipment shall
be removed from service until repaired and a record made listing the date,
equipment involved, inspection and maintenance operations performed, any
defects found, and any actions taken to correct the defects. Records shall be
retained for 3 years after the defect is found.
c)
Removal of a sealed source from a source holder or logging tool and
maintenance on sealed sources or holders in which sealed sources are contained
may not be performed by the licensee unless a written procedure developed
pursuant to Section 351.630 has been approved by the Agency pursuant to Section
351.130(c) or by the U.S. Nuclear Regulatory Commission or an Agreement State.
d)
If a sealed source is stuck in the source holder, the licensee may not
perform any operation, such as drilling, cutting, or chiseling, on the source
holder unless the licensee is specifically approved by the Agency, the U.S.
Nuclear Regulatory Commission, or an Agreement State to perform this operation.
e)
The repair, opening, or modification of any sealed source shall be
performed only by persons specifically authorized to do so by the Agency, the
U.S. Nuclear Regulatory Commission, or an Agreement State.