32 Ill. Adm. Code 422.APPENDIX B
B Recommended Testing Strategy for Measurements in Buildings Involved in Real Estate Transactions
Section 422.APPENDIX B Recommended
Testing Strategy for Measurements in Buildings Involved in Real Estate
Transactions
The first step is to perform a
short-term measurement* in the lowest structural areas**.
Perform
a Short-Term Test
The minimum length
of a short-term test shall be 48 hours.
There are 2 methods that may be
used for short-term testing during a Real Estate transaction.
(1) Simultaneous Tests – Two
short-term tests set side by side conducted simultaneously.
(2)
Continuous Monitor Testing – A Continuous Monitor that measures in hourly
increments.
If the result is less than 4.0 pCi/L
If the result is 4.0 pCi/L or more
No further action is required. Retest in two years
or if any renovations or additions are made to the building.
Fix the home.
* Short-term
tests may last between 2 and 90 days, most last between 2 and 7 days. Tests
between seven and 90 days are usually impractical for real estate transactions
but are fine for homeowners assessing their own radon situation. Examples of
short-term detectors used in home environment testing include: activated
charcoal canisters, charcoal liquid scintillation vials, electret chambers and
continuous monitors.
** Conduct
a short-term test in each of the lowest structural areas suitable for occupancy
in the home. For example, if the home is a split-level building with one or
more foundation types: test in the basement, in a room over the crawlspace and
in a slab-on-grade room. In accordance with this protocol, measurement professionals
are required to test in each of the foundation types.