32 Ill. Adm. Code 605.60
Qualifications of the Employees of the Firm
Section 605
Section 605.60
Qualifications of the Employees of the Firm
a) Because the contractor and its subcontractors will be
responsible for performing a variety of activities, as set forth in this Part
and 32 Ill. Adm. Code 601, ranging from designing a facility to negotiating
plans for impact assistance with local governments, when selecting a contractor
to design, develop, construct, operate and close a low-level radioactive waste
disposal facility, the Agency will only select a proposer that has or will
obtain a qualified staff that will be assigned to the project and that meets
the requirements of this Section. The employee qualifications listed in this
Section are minimum requirements for the contractor and must be met
collectively by the contractor's staff; the qualifications need not be met by a
single individual.
1) Project Manager
A) The contractor selected shall have an identified individual (or
individuals) who will act as Project Manager for the designing, development,
construction, operation and closure of the low-level radioactive waste disposal
facility.
B) The Project Manager will be required to work with the Agency to
ensure that the project is proceeding in accordance with the provisions of the
contract and in accordance with the requirements of the Act.
C) The Project Manager will also be responsible for organizing,
managing and coordinating the staff of both the contractor and the
subcontractors. To assure that the Project Manager is capable of fulfilling
these responsibilities, the Project Manager must have previous managerial
experience on a project of similar magnitude and complexity (i.e., project of
similar budget, duration, staffing, and regulatory complexity). The Project
Manager must have been manager of a project that involved supervision of at
least 30 professional (engineering or other technical) employees.
Additionally, the Project Manager must be familiar with federal, State and
local requirements applicable to radioactive or hazardous waste disposal, or
with radioactive materials licensing. The Project Manager's familiarity with
these regulatory requirements shall have been obtained through involvement on
previous projects.
2) Senior Project Engineer. The Senior Project Engineer will be
responsible for approving all engineering plans, designs, drawings, reports,
specifications and other engineering documents on behalf of the contractor.
Therefore, the Senior Project Engineer shall:
A) Be a Professional Engineer licensed in Illinois by the
Department of Financial and Professional Regulation in accordance with the
Illinois Professional Engineering Practice Act of 1989 [225 ILCS 325] or be a
Professional Engineer licensed in another state and be eligible for reciprocal licensure
within six months; and
B) Have been a senior engineer on at least two other engineering
projects of similar complexity and magnitude as the proposed project (i.e.,
project of similar budget, duration, staffing and regulatory complexity).
Preference will be given to proposers who designate as a senior engineer an
individual who has worked on a project for the design, development, or
remediation of a radioactive waste disposal facility.
3) Mechanical Engineer. If the proposer's plan requires the
services of a mechanical engineer, the mechanical engineer shall:
A) Be a Professional Engineer licensed in Illinois by the
Department of Financial and Professional Regulation in accordance with the
Professional Engineering Practice Act of 1989 [225 ILCS 325] or be a
Professional Engineer licensed in another state and be eligible for reciprocal licensure
within six months; or
B) Have a degree in mechanical engineering and at least five years
experience as a mechanical engineer.
4) Geotechnical or Civil Engineer. The geotechnical or civil
engineer shall:
A) Be a Professional Engineer licensed in Illinois by the
Department of Financial and Professional Regulation in accordance with the
Professional Engineering Practice Act of 1989 [225 ILCS 325] or be a Registered
Professional Engineer licensed in another state and be eligible for reciprocal licensure
within six months; or
B) Have a degree in geotechnical or civil engineering and at least
five years experience as a geotechnical or civil engineer.
5) Structural Engineer. The Structural Engineer will be
responsible for designing structural components of the facility. To be able to
accomplish this task, the structural engineer will have to be knowledgeable in
reinforced concrete design and construction. At a minimum, the individual
identified to perform these responsibilities shall:
A) Be a Structural Engineer licensed in Illinois by the Department
of Financial and Professional Regulation in accordance with the Structural
Engineering Practice Act of 1989 [225 ILCS 340] or be a Structural Engineer licensed
in another state and be eligible for reciprocal licensure within six months;
and
B) Shall have at least 10 years of experience in reinforced
concrete design and construction.
6) Geohydrologist. The proposer selected as contractor shall have
a geohydrologist knowledgeable in geologic interpretation and hydraulic
transport of contaminants through soil or other porous material. The
geohydrologist shall either:
A) Hold a Master's Degree in geology or hydrogeology and have at
least five years experience as a hydrogeologist; or
B) Hold a Bachelor's degree in geology and have at least eight
years of experience as hydrogeologist.
7) Environmental Scientist. The proposer selected as contractor
shall have an environmental scientist who:
A) Holds an advanced degree (Ph.D., M.A. or M.S.) in Environmental
Science or related natural or physical science; and
B) Has at least five years experience in evaluation and mitigation
of environmental impacts.
8) Health Physicists
A) During the design, development and planning of operation of a
low-level radioactive waste disposal facility, the full time services of a
health physicist will be required to establish compliance with the requirements
of 32 Ill. Adm. Code 310, 330, 341, 400 and 601. The health physicist will be
responsible for developing and implementing an environmental monitoring plan,
preparing an emergency response plan, and assisting the contractor in the
design and development of a disposal facility that incorporates the best available
management technologies that are economically reasonable, technologically
feasible and environmentally sound. In order to assure that the health
physicist available to the contractor is competent to fulfill these
responsibilities, the contractor selected must have a health physicist whose
services will be dedicated to the project and who meets one of the following:
i) Is certified by the American Board of Health Physics, 1313
Dolley Madison Blvd., Suite 402, McLean VA 22101, in accordance with that organization's
standards for certification in effect in November 2011. A copy of these
standards is available from the Agency;
ii) Holds a Doctorate (Ph.D.) in health physics, medical
radiological physics or physics, and has at least three years of applied
radiation protection experience; or
iii) Holds a Master's (M.S., M.A.) degree in health physics or
physics and has at least five years of applied radiation protection experience.
B) Operation. During the operation of the low-level radioactive
waste disposal facility, health physicists will be needed to conduct personnel
monitoring, perform environmental monitoring, inspect packages received for
disposal, and perform the responsibilities of a Radiation Safety Officer. In
order to assure that the health physicists available to the contractor are
capable of performing duties necessary to establish compliance with the
requirements of 32 Ill. Adm. Code 340 and 601, the contractor selected must
have health physicists whose services will be dedicated, i.e., a full-time
employee on site, to the operation of the low-level radioactive waste disposal
facility. In addition, the health physicists must either:
i) Be certified by the American Board of Health Physics, 1313
Dolley Madison Blvd, Suite 402, McLean VA 22101, in accordance with that organization's
standards for certification in effect in November 2011. A copy of these
standards is available from the Agency;
ii) Hold a Doctorate (Ph.D.) in health physics, physics or
natural or physical science and have at least three years of applied radiation
protection experience;
iii) Hold a Master's (M.S., M.A.) degree in health physics,
physics or natural or physical science and have at least five years of applied
radiation protection experience; or
iv) Hold a Bachelor's (B.S., B.A.) degree in health physics,
physics, or natural or physical science and have at least eight years of
applied radiation protection experience.
9) Radiochemist. The contractor will be required to operate an
onsite radiochemistry laboratory. This laboratory will be used to analyze
incoming radioactive materials, as well as samples obtained in the process of
environmental monitoring. The radiochemist will be responsible for managing
this laboratory and performing chemical analyses. In order to ensure that the
contractor will be able to fulfill its obligation to provide radiochemistry
support services, the proposer selected must have a radiochemist who:
A) Holds an advanced degree (Ph.D., M.A., M.S.) in radiochemistry
or chemistry; and
B) Has at least five years experience working in a radiochemistry
laboratory.
10) Community Liaison. The community liaison will be responsible
for involving all segments of the public in the decision making surrounding the
development, operation, closure and post-closure phases of the facility and
will also be responsible for establishing a long-term local citizens' advisory
group. To ensure that the community liaison is capable of fulfilling these
responsibilities, the proposer selected must have a community liaison who will
be assigned to this project and who either has:
A) An advanced degree (Ph.D., M.S., M.A.) in public administration
or a related field, e.g., public affairs, or technology and public policy, and
a minimum of three years experience in conducting public participation
programs, particularly those involving the siting of locally controversial land
uses, such as prisons or landfills; or
B) A Bachelor's degree (B.A., B.S.) in public administration or a
related field and a minimum of five years experience in conducting public
participation programs, particularly those involving the siting of locally
controversial land uses.
11) Support Services
A) Comptroller – The contractor shall dedicate to the project the
full-time services of a comptroller experienced in managing projects of similar
budget size and complexity of the proposed project. The comptroller shall hold
a degree in accounting and shall have at least five years experience.
B) Information Management Services Staff. The contractor will be
responsible for developing and maintaining computerized record keeping systems that
track generators, container contents, shippers, dates, certifications,
treatments, package characteristics, special disposal requirements and location
of containers in disposal units. These computerized record keeping systems
must be compatible with the Agency's systems. To ensure that the contractor is
capable of fulfilling this responsibility, the proposer shall have an
information management specialist who has training in the development and
maintenance of computer systems. The information management specialist shall
hold a Bachelor's or graduate level degree in computer science or information
management and shall have at least three years of computer programming
experience.
b) The Agency shall evaluate the qualifications of any other
project staff identified by the proposer in its proposal. When determining
whether the staff is qualified to perform the responsibilities identified in
the proposal, the Agency will evaluate staff qualifications as characterized by
the proposer in the proposal. In addition, the Agency will evaluate the
qualifications specified by the proposer for positions that have been identified
but not yet filled in order to determine whether the proposer anticipates
filling vacant positions with individuals competent to perform assigned tasks.
The Agency also will evaluate the proposer's procedures for hiring qualified
replacements when the identified staff leaves the employ of the proposer.