35 Ill. Adm. Code 106.202
Petition Requirements
Section 106
Section 106.202Â Petition
Requirements
a)        Heated Effluent Demonstration. The petition must include the
following information but may include additional information that the
petitioner believes will be relevant to the proceeding:
1)Â Â Â Â Â Â Â Â General Plant Description:
A)Â Â Â Â Â Â Â Generating capacity;
B)Â Â Â Â Â Â Â Type of fuel used;
C)Â Â Â Â Â Â Â Operating characteristics of the condenser cooling system;
D)Â Â Â Â Â Â Â History of the load factor of the plant for the time during
which the plant has operated, but for no more than the last 5 years;
E)Â Â Â Â Â Â Â Projected load factors for the life of the plant;
F)Â Â Â Â Â Â Â Â Estimated date of retirement for each unit at the plant and
any plans for additional units at the plant;
G)Â Â Â Â Â Â Â History of plant shutdowns; and
H)Â Â Â Â Â Â Â Planned, emergency, and projected shutdowns with frequency and
duration.
2)Â Â Â Â Â Â Â Â Description of Method for Heat Dissipation:
A)Â Â Â Â Â Â Â Type of system used (such as once-through, mechanical, and
draft cooling towers) in narrative form; and
B)Â Â Â Â Â Â Â Summary information on temperature of discharge to receiving
waters in narrative form.
3)Â Â Â Â Â Â Â Â Plume Studies:
A)Â Â Â Â Â Â Â Actual plume studies in the last 5 years correlated with plant
operation and meteorological conditions;
B)Â Â Â Â Â Â Â Theoretical plume studies for all four seasons for typical and
worst case conditions. Worst case conditions must be identified as worst
conditions of plant load factors, precipitation, ambient water temperature, and
air temperature; the studies must consider the frequency of occurrence and
their joint probabilities of occurrence; and
C)       Theoretical plume studies that identify isotherms at 3°
Fahrenheit (1.7° Centigrade) intervals down to ambient temperature indicating
three-dimensional effects.
4)Â Â Â Â Â Â Â Â A demonstration, which may take any of the forms described in
subsection (b)(2), that discharges from the source of heated effluent have not
caused and cannot be reasonably expected to cause significant ecological damage
to the receiving waters, including:
A)Â Â Â Â Â Â Â Biological studies in the last 5 years on receiving waters,
including species studied, location of studies, and conclusions reached,
including conclusions as to both the lethal and sublethal effects of the
thermal discharge;
B)Â Â Â Â Â Â Â The impact on other animal life (such as waterfowl and
amphibians) in the area as a result of the thermal discharge; and
C)Â Â Â Â Â Â Â Secondary Considerations
i)Â Â Â Â Â Â Â Â Â Possible and known impact on recreation from thermal
discharges; and
ii)Â Â Â Â Â Â Â Â Management practices employed or planned in order to limit
the effect of any environmental harm established under this subsection (a)(4).
5)Â Â Â Â Â Â Â Â A citation to any prior proceedings, in which the petitioner
was a party, brought under 35 Ill. Adm. Code 302.211(f) or (j)(3).
b)        Artificial Cooling Lake Demonstration. The petition must
include the following information but may include additional information that
the petitioner believes will be relevant to the proceeding:
1)Â Â Â Â Â Â Â Â A demonstration that the artificial cooling lake receiving the
heated effluent will be environmentally acceptable and within the intent of the
Act, including:
A)Â Â Â Â Â Â Â Provision of conditions capable of supporting shellfish, fish
and wildlife, and recreational uses consistent with good management practices;
and
B)Â Â Â Â Â Â Â Control of the thermal component of the discharger's effluent
by a technologically feasible and economically reasonable method.
2)Â Â Â Â Â Â Â Â The demonstration required under subsection (b)(1) may take
the form of any of the following:
A)Â Â Â Â Â Â Â A final environmental impact statement;
B)Â Â Â Â Â Â Â Pertinent provisions of environmental assessments used to
prepare the final environmental impact statement; or
C)Â Â Â Â Â Â Â A showing under Section 316(a) of the Clean Water Act (33 USC
1326).
3)Â Â Â Â Â Â Â Â A citation to any prior proceedings, in which the petitioner
was a party, brought under 35 Ill. Adm. Code 302.211(f) or (j)(3).
c)        Sulfur Dioxide Demonstration. The petition must include the
following information:
1)Â Â Â Â Â Â Â Â An explicit statement of the site-specific emission limitation
(in pounds of sulfur dioxide per million British thermal units (btu) actual
heat input and total pounds of sulfur dioxide per hour) that is proposed for
the facility.
2)Â Â Â Â Â Â Â Â Emission Sources Description:
A)Â Â Â Â Â Â Â The diameter, height, exit gas temperature, and exit gas
velocity for all stacks or vents through which sulfur dioxide is emitted into
the atmosphere;
B)Â Â Â Â Â Â Â A description of the fuels used including type, ultimate
analysis, sulfur content, and heat content;
C)Â Â Â Â Â Â Â A description of the type of fuel combustion equipment
including method of firing and size (in million btu per hour capacity);
D)Â Â Â Â Â Â Â A topographic map of terrain within 30 miles of the emission source
or sources;
E)Â Â Â Â Â Â Â A specific description of the location of the emission sources,
including a plot plan; and
F)Â Â Â Â Â Â Â Â A specific description of the operating conditions that
produce maximum sulfur dioxide emissions.
3)Â Â Â Â Â Â Â Â A summary of any and all ambient air quality data collected by
the owner or operator of the source or sources since January 1, 1973. The
summary must include annual averages; maximum and second-highest one-hour,
3-hour, and 24-hour averages for each month; and the number of times the 3-hour
and 24-hour sulfur dioxide standards were exceeded during each month.
4)Â Â Â Â Â Â Â Â A summary of any and all meteorological data collected by the
owner or operator of the source or sources since January 1, 1973, if the data
are used in the development of the site-specific emission standard.
5)Â Â Â Â Â Â Â Â A complete description of and justification for all dispersion
models and plume rise equations that are used to develop the site-specific
emission limitation, including all model equations.
6)Â Â Â Â Â Â Â Â A description of and justification for the use of all data
that were inputs to the dispersion and plume rise formula used to establish the
site-specific emission standard. The description and justification must cover,
as a minimum, the following input data:
A)Â Â Â Â Â Â Â Stack diameters, stack heights, exit gas temperatures, and exit
gas velocities for all stacks and vents emitting sulfur dioxide at the subject
facility as well as for any other sources of sulfur dioxide that were modeled;
B)Â Â Â Â Â Â Â All sulfur dioxide emission sources that were modeled; and
C)Â Â Â Â Â Â Â All meteorological data.
7)Â Â Â Â Â Â Â Â Calculated maximum ground-level concentrations using the
following method, or such other method (or modification of the hereinafter
stated method) that the petitioner proves to the satisfaction of the Board to
be acceptable.
A)Â Â Â Â Â Â Â Selection of simulation model:
i)Â Â Â Â Â Â Â Â Â Gaussian models that allow the input of hourly meteorological
data must be used which are appropriate for the specific location and type of source
or sources in question.
ii)Â Â Â Â Â Â Â Â Dispersion models presented in "Guidelines on Air
Quality Models" (EPA-450/2-78-027), or those deemed by the Board to be
equivalent to these models must be used for detailed air quality studies.
B)Â Â Â Â Â Â Â Selection of meteorological data and stack parameters:
i)Â Â Â Â Â Â Â Â Â The most recent 5 years of hour-by-hour meteorological data
reasonably available, including wind speed, wind direction, atmospheric
stability, mixing height and surface temperature must be used, unless the
petitioner demonstrates that one of the 5 years causes substantially higher
concentrations than the other four, in which case detailed analyses conducted
for only that "worst case" year would be acceptable. Notwithstanding
the previous sentence, one year of on-site data may be used in lieu of the
5-year data requirement;
ii)Â Â Â Â Â Â Â Â Data must be from the nearest, representative, quality
controlled meteorological collecting site; and
iii)Â Â Â Â Â Â Â Stack parameters (including emission rate, stack height,
stack diameter, exit velocity, and exit temperature) must reflect the maximum
operating rate for comparison with the 24-hour and 3-hour sulfur dioxide
standards.
C)Â Â Â Â Â Â Â Receptors:
i)Â Â Â Â Â Â Â Â Â Receptors must be located so as to ensure that the source's
maximum impact is detected; and
ii)Â Â Â Â Â Â Â Â The determination of the receptor grid must be fully
documented in the modeling study;
D)Â Â Â Â Â Â Â Special conditions:
i)Â Â Â Â Â Â Â Â Â All special conditions that may affect the dispersion of the
effluent plume, including local terrain effects and aerodynamic downwash, must
be considered in the modeling study;
ii)Â Â Â Â Â Â Â Â If terrain is a factor in the vicinity of the source, a model
capable of handling variable-height receptors must be used; and
iii)Â Â Â Â Â Â Â If the computed height of the effluent plume is less than 2.5
times the height of nearby buildings or local obstructions, aerodynamic
downwash must be studied and considered as a possible factor in the dispersion
of that effluent.
E)Â Â Â Â Â Â Â Determination of violation:Â The determination of whether an
applicable air quality increment or standard is being violated must be based on
the second-highest predicted concentration over the receptor grid for
short-term averaging times and on the highest predicted concentration for
annual averaging times. However, if only one year of meteorological data is
used in the short-term analysis, then the highest predicted concentration may
be compared to the applicable standard to determine whether a violation has
occurred.
F)Â Â Â Â Â Â Â Â Other sources:Â Effects of other sources of sulfur dioxide
must be taken into account in the modeling study. Methods by which other
sources of sulfur dioxide may be accounted are as follows:
i)Â Â Â Â Â Â Â Â Â An acceptable method is to estimate the
"background" from monitoring data which has been subjected to
adequate quality control where available. When monitored data is used, the
background must be estimated using monitoring days with meteorological
conditions similar to those identified as "worst case" for the source
in question; or
ii)Â Â Â Â Â Â Â Â If monitoring data is not available, then all sources of
sulfur dioxide having a significant impact in the area of the source's impact
area must be used in the simulation model. These sources of sulfur dioxide
must also be modeled at their maximum allowable emission rate for any studies
addressing 24-hour or 3-hour averaging times.
8)Â Â Â Â Â Â Â Â Estimates of the frequency, characteristics, probable time of
occurrence, and duration of the meteorological conditions associated with the
maximum ground-level concentration of sulfur dioxide to which the facility
under study contributes. A description of the techniques used in arriving at
the above estimates must be included.
9)Â Â Â Â Â Â Â Â Background concentrations that were determined for all
meteorological conditions required to be examined under subsection (c)(7) and
for any other meteorological conditions considered in the development of the
alternative standard.
10)Â Â Â Â Â Â Â Â A description of the method that was used to determine
background sulfur dioxide concentrations in the vicinity of the subject
facility for each of the meteorological conditions required to be examined
under subsection (c)(7) and for any additional meteorological conditions
considered in developing the alternative standard.
11)Â Â Â Â Â Â Â Â An evaluation and calibration of the dispersion model if air
quality monitoring data were available to perform the evaluation and
calibration.
12)Â Â Â Â Â Â Â Â A
statement that the procedural requirements of 40 CFR 51.4 (1977) are met. At
least 30 days prior to the date of the hearing, the petitioner must:
A)Â Â Â Â Â Â Â Give
notice to the public, by prominent advertisement in the Air Quality Control
Region affected, announcing the date, time, and place of the hearing;
B)Â Â Â Â Â Â Â Make
available a copy of the petition for public inspection in at least one location
in the Air Quality Control Region in which the source is located;
C)Â Â Â Â Â Â Â Notify
the Administrator of USEPA (through the Region V Office);
D)Â Â Â Â Â Â Â Notify
each local air pollution control agency located within the affected Air Quality
Control Region; and
E)Â Â Â Â Â Â Â Notify,
in the case of an interstate Air Quality Control Region, any air pollution
control agencies of other states included, in whole or in part, in the Region.