35 Ill. Adm. Code 1100.212
Use of Painted CCDD as Fill Material
Section 1100.212Â Use of Painted CCDD as Fill Material
a)Â Â Â Â Â Â Â Â For
purposes of this Part, uncontaminated broken concrete without protruding metal
bars, bricks, rock, stone, or reclaimed or other asphalt pavement that has been
painted (painted CCDD) may be used as fill material at a CCDD fill operation if
it is evaluated analytically under the supervision of a PE or PG and if all
requirements of this Section are satisfied. Acceptance or management of
painted CCDD for any purpose other than use as fill material at a CCDD fill
operation must be in accordance with applicable law and may require permits or
beneficial use determinations from the Agency. Such other purposes include,
but are not limited to, processing of painted CCDD for reuse.
1)Â Â Â Â Â Â Â Â The
PE or PG must determine, on a site-specific basis, the number and location of
paint samples that will provide a representative analysis of paint from the
painted CCDD to be used as fill material.
2)Â Â Â Â Â Â Â Â The
PE or PG must obtain paint samples consisting of representative paint chips or
scrapings that include all layers of paint in the area sampled and that
minimize the amount of substrate in the sample.
3)Â Â Â Â Â Â Â Â Paint
samples must be analyzed for arsenic, cadmium, chromium (total), lead, mercury
and zinc (contaminants of concern) using the TCLP or SPLP extraction test
analytical procedures in accordance with Methods 1311 and 1312, respectively,
in "Test Methods for Evaluating Solid Wastes, Physical/Chemical Methods,"
USEPA Publication No. SW-846, incorporated by reference in Section 1100.104.
A)Â Â Â Â Â Â Â Paint
samples must not be composited for analysis, and analytical results from paint
samples must not be averaged.
B)Â Â Â Â Â Â Â All
quantitative analyses of paint samples must be completed by an accredited
laboratory in accordance with the requirements of 35 Ill. Adm. Code 186 and the
scope of the accreditation.
C)Â Â Â Â Â Â Â Documentation
of any chemical analysis must include, but is not limited to:
i)Â Â Â Â Â Â Â Â Â Chain
of custody control;
ii)Â Â Â Â Â Â Â Â A
copy of the lab analysis;
iii)Â Â Â Â Â Â Â Accreditation
status of the laboratory performing the analysis; and
iv)Â Â Â Â Â Â Â Certification
by an authorized agent of the laboratory that the analysis has been performed
in accordance with 35 Ill. Adm. Code 186, the Agency's rules for the
accreditation of environmental laboratories and the scope of the accreditation.
4)Â Â Â Â Â Â Â Â For
painted CCDD to be used as fill material, analytical results for each paint
sample must not exceed the chemical-specific Class I groundwater quality
standard at 35 Ill. Adm. Code 620.410 for any contaminant of concern identified
in subsection (a)(3) of this Section.
b)Â Â Â Â Â Â Â Â Notwithstanding
subsection (a) of this Section, broken concrete, asphalt pavement, and other
roadway CCDD with pavement markings, including but not limited to striping, may
be used as fill material at a CCDD fill operation provided that:
1)Â Â Â Â Â Â Â Â The
pavement markings comply with IDOT specifications for pavement markings; and
2)Â Â Â Â Â Â Â Â The
CCDD is accompanied by a PE or PG certification, on forms prescribed by the
Agency, affirming that the pavement markings comply with IDOT specifications
for pavement markings found at Section 1095 of IDOT's "Standard
Specifications for Road and Bridge Construction".