35 Ill. Adm. Code 203.1170
Excessive Concentration
Section 203.1170Â Excessive
Concentration
"Excessive concentration" is defined for the
purposes of determining good engineering practice stack height under Section
203.1200(a)(3) and means:
a)Â Â Â Â Â Â Â Â For
sources seeking credit for stack height exceeding that established under Section
203.1200(a)(2), a maximum ground-level concentration due to emissions from a
stack due in whole or part to downwash, wakes, and eddy effects produced by
nearby structures or nearby terrain features that individually is at least 40%
in excess of the maximum concentration experienced in the absence of such
downwash, wakes, or eddy effects and that contributes to a total concentration
due to emissions from all sources that is greater than an ambient air quality
standard. For sources subject to this Part, an excessive concentration
alternatively means a maximum ground-level concentration due to emissions from
a stack due in whole or part to downwash, wakes, or eddy effects produced by
nearby structures or nearby terrain features that individually is at least 40%
in excess of the maximum concentration experienced in the absence of the downwash,
wakes, or eddy effects and greater than an ambient air increment under 35 Ill.
Adm. Code 204.900. The allowable emission rate to be used in making
demonstrations of excessive concentration shall be prescribed by the NSPS that
is applicable to the source category unless the owner or operator demonstrates
that this emission rate is infeasible. When those demonstrations are approved
by the Agency, an alternative emission rate shall be established in
consultation with the source owner or operator.
b)Â Â Â Â Â Â Â Â For
sources seeking credit for increases in existing stack heights up to the
heights established under Section 203.1200(a)(2), either:
1)Â Â Â Â Â Â Â Â A
maximum ground-level concentration due in whole or part to downwash, wakes or
eddy effects as provided in subsection (a), except that the emission rate
specified by the SIP (or, in the absence of such a limit, the actual emission
rate) shall be used; or
2)Â Â Â Â Â Â Â Â The
actual presence of a local nuisance caused by the existing stack, as determined
by the Agency; and
c)Â Â Â Â Â Â Â Â For
sources seeking credit for a stack height determined under Section
203.1200(a)(2) when the Agency requires the use of a field study or fluid model
to verify good engineering practice stack height, for sources seeking stack
height credit based on the aerodynamic influence of cooling towers, and for
sources seeking stack height credit based on the aerodynamic influence of
structures not adequately represented by the equations in Section 203.1200(a)(2),
a maximum ground-level concentration due in whole or part to downwash, wakes or
eddy effects that is at least 40% in excess of the maximum concentration
experienced in the absence of such downwash, wakes, or eddy effects.