35 Ill. Adm. Code 203.1200
Good Engineering Practice
Section
203.1200Â Good Engineering Practice
a)Â Â Â Â Â Â Â Â "Good
engineering practice", with respect to stack height, means the greater of:
1)Â Â Â Â Â Â Â Â 65
meters, measured from the ground-level elevation at the base of the stack;
2)Â Â Â Â Â Â Â Â The following:
A)Â Â Â Â Â Â Â For a
stack in existence on January 12, 1979, and for which the owner or operator had
obtained all necessary preconstruction approvals or permits required under 40
CFR Parts 51 and 52 (incorporated by reference in 35 Ill. Adm. Code 204.100):
H
g
= 2.5H,
provided the owner or operator
produces evidence that this equation was actually relied on in establishing an
emission limitation;
B)Â Â Â Â Â Â Â For
all other stacks:
H
g
= H + 1.5L
where:
H
g
=
good engineering practice stack height, measured from the ground-level
elevation at the base of the stack;
H
=
height of nearby structure or structures measured from the
ground-level elevation at the base of the stack;
L
=
lesser dimension, height or projected width, of nearby
structure or structures provided that USEPA or the Agency may require the use
of a field study or fluid model to verify good engineering practice stack
height for the source; or
3)Â Â Â Â Â Â Â Â The height demonstrated by a fluid model or a
field study approved by USEPA or the Agency that ensures the emissions from a
stack do not result in excessive concentrations of any air pollutant as a
result of atmospheric downwash, wakes, or eddy effects created by the source
itself, nearby structures, or nearby terrain features.
b)Â Â Â Â Â Â Â Â For purposes
of this definition, "stack" means any point in a source designed to
emit solids, liquids, or gases into the air, including a pipe or duct but not
including flares.