35 Ill. Adm. Code 204.1880
Monitoring Requirements
Section 204.1880Â Monitoring Requirements
a)Â Â Â Â Â Â Â Â General
Requirements
1)Â Â Â Â Â Â Â Â Each
PAL permit must contain enforceable requirements for the monitoring system that
accurately determines plantwide emissions of the PAL pollutant in terms of mass
per unit of time, or in CO
2
e per unit of time for a GHG PAL. Any
monitoring system authorized for use in the PAL permit must be based on sound
science and meet generally acceptable scientific procedures for data quality
and manipulation. Additionally, the information generated by such system must
meet minimum legal requirements for admissibility in a judicial proceeding to
enforce the PAL permit.
2)Â Â Â Â Â Â Â Â The
PAL monitoring system must employ one or more of the four general monitoring
approaches meeting the minimum requirements set forth in subsection (b) and
must be approved by the Agency.
3)Â Â Â Â Â Â Â Â Notwithstanding
subsection (a)(2), the owner or operator may also employ an alternative
monitoring approach that meets subsection (a)(1) if approved by the Agency.
4)Â Â Â Â Â Â Â Â Failure
to use a monitoring system that meets the requirements of this Section renders
the PAL invalid.
b)Â Â Â Â Â Â Â Â Minimum
Performance Requirements for Approved Monitoring Approaches. Â The following are
acceptable general monitoring approaches when conducted in accordance with the
minimum requirements in subsections (c) through (i):
1)Â Â Â Â Â Â Â Â Mass
balance calculations for activities using coatings or solvents;
2)Â Â Â Â Â Â Â Â CEMS;
3)Â Â Â Â Â Â Â Â CPMS
or PEMS; and
4)Â Â Â Â Â Â Â Â Emission
factors.
c)Â Â Â Â Â Â Â Â Mass
Balance Calculations. An owner or operator using mass balance calculations to
monitor PAL pollutant emissions from activities using coating or solvents shall
meet the following requirements:
1)Â Â Â Â Â Â Â Â Provide
a demonstrated means of validating the published content of the PAL pollutant
that is contained in or created by all materials used in or at the emissions
unit;
2)Â Â Â Â Â Â Â Â Assume
that the emissions unit emits all of the PAL pollutant that is contained in or
created by any raw material or fuel used in or at the emissions unit, if it
cannot otherwise be accounted for in the process; and
3)Â Â Â Â Â Â Â Â When
the vendor of a material or fuel, that is used in or at the emissions unit,
publishes a range of pollutant content from that material, the owner or
operator must use the highest value of the range to calculate the PAL pollutant
emissions unless the Agency determines there is site-specific data or a
site-specific monitoring program to support another content within the range.
d)Â Â Â Â Â Â Â Â CEMS.Â
An owner or operator using CEMS to monitor PAL pollutant emissions shall meet
the following requirements:
1)Â Â Â Â Â Â Â Â CEMS
must comply with applicable Performance Specifications found in 40 CFR 60, appendix
B (incorporated by reference in Section 204.100); and
2)Â Â Â Â Â Â Â Â CEMS
must sample, analyze and record data at least every 15 minutes while the
emissions unit is operating.
e)Â Â Â Â Â Â Â Â CPMS
or PEMS. An owner or operator using CPMS or PEMS to monitor PAL pollutant
emissions shall meet the following requirements:
1)Â Â Â Â Â Â Â Â The
CPMS or the PEMS must be based on current site-specific data demonstrating a
correlation between the monitored parameter or parameters and the PAL pollutant
emissions across the range of operation of the emissions unit; and
2)Â Â Â Â Â Â Â Â Each
CPMS or PEMS must sample, analyze, and record data at least every 15 minutes,
or at another less frequent interval approved by the Agency, while the
emissions unit is operating.
f)Â Â Â Â Â Â Â Â Emission
Factors. An owner or operator using emission factors to monitor PAL pollutant
emissions shall meet the following requirements:
1)Â Â Â Â Â Â Â Â All
emission factors shall be adjusted, if appropriate, to account for the degree
of uncertainty or limitations in the factors' development;
2)Â Â Â Â Â Â Â Â The
emissions unit shall operate within the designated range of use for the
emission factor, if applicable; and
3)Â Â Â Â Â Â Â Â If
technically practicable, the owner or operator of a significant emissions unit
that relies on an emission factor to calculate PAL pollutant emissions shall
conduct validation testing to determine a site-specific emission factor within
6 months after PAL permit issuance, unless the Agency determines that testing
is not required.
g)Â Â Â Â Â Â Â Â A
source owner or operator must record and report maximum potential emissions
without considering enforceable emission limitations or operational
restrictions for an emissions unit during any period of time that there is no
monitoring data, unless another method for determining emissions during those
periods is specified in the PAL permit.
h)Â Â Â Â Â Â Â Â Notwithstanding
the requirements of subsections (c) through (g), when an owner or operator of
an emissions unit cannot demonstrate a correlation between the monitored
parameter or parameters and the PAL pollutant emissions rate at all operating
points of the emissions unit, the Agency shall, at the time of permit issuance:
1)Â Â Â Â Â Â Â Â Establish
a default value or values for determining compliance with the PAL based on the
highest potential emissions reasonably estimated at the operating point or
points; or
2)Â Â Â Â Â Â Â Â Determine
that operation of the emissions unit during operating conditions when there is
no correlation between monitored parameter or parameters and the PAL pollutant
emissions is a violation of the PAL.
i)Â Â Â Â Â Â Â Â Â Revalidation.Â
All data used to establish the PAL pollutant must be revalidated through
performance testing or other scientifically valid means approved by the Agency.Â
The testing must occur at least once every 5 years after issuance of the PAL.