35 Ill. Adm. Code 204.380
Excessive Concentration
Section 204.380 Excessive Concentration
"Excessive concentration" is defined for the
purpose of determining good engineering practice stack height under Section
204.420(a)(3) and means:
a) For
sources seeking credit for stack height exceeding that established under
Section 204.420(a)(2), a maximum ground-level concentration due to emissions
from a stack due in whole or part to downwash, wakes, and eddy effects produced
by nearby structures or nearby terrain features that individually is at least
40 percent in excess of the maximum concentration experienced in the absence of
such downwash, wakes, or eddy effects and that contributes to a total
concentration due to emissions from all sources that is greater than an ambient
air quality standard. For sources subject to this Part, an excessive
concentration alternatively means a maximum ground-level concentration due to
emissions from a stack due in whole or part to downwash, wakes, or eddy effects
produced by nearby structures or nearby terrain features that individually is
at least 40 percent in excess of the maximum concentration experienced in the
absence of the downwash, wakes, or eddy effects and greater than an ambient air
increment under Section 204.900. The allowable emission rate to be used in
making demonstrations of excessive concentration shall be prescribed by the
NSPS that is applicable to the source category unless the owner or operator
demonstrates that this emission rate is infeasible. When those demonstrations
are approved by the Agency, an alternative emission rate shall be established
in consultation with the source owner or operator.
b) For
sources seeking credit for increases in existing stack heights up to the
heights established under Section 204.420(a)(2), either:
1) A
maximum ground-level concentration due in whole or part to downwash, wakes or
eddy effects as provided in subsection (a), except that the emission rate
specified by the SIP (or, in the absence of such a limit, the actual emission
rate)
shall
be used; or
2) The
actual presence of a local nuisance caused by the existing stack, as determined
by the Agency; and
c) For
sources seeking credit for a stack height determined under Section 204.420(a)(2)
when the Agency requires the use of a field study or fluid model to verify good
engineering practice stack height, for sources seeking stack height credit
based on the aerodynamic influence of cooling towers, and for sources seeking
stack height credit based on the aerodynamic influence of structures not
adequately represented by the equations in Section 204.420(a)(2), a maximum
ground-level concentration due in whole or part to downwash, wakes or eddy
effects that is at least 40 percent in excess of the maximum concentration
experienced in the absence of the downwash, wakes, or eddy effects.