35 Ill. Adm. Code 215.437
Open-Ended Valves
Section 215
Section 215.437 Open-Ended
Valves
a) Each open-ended valve shall be equipped with a cap, blind
flange, plug, or a second valve, except during operations requiring fluid flow
through the open-ended valve.
b) Each open-ended valve equipped with a second valve shall be
operated in a manner such that the valve on the process fluid end is closed
before the second valve is closed.
c) Components which are open-ended valves and which serve as a
sampling connection shall be controlled such that:
1) A closed purge system or closed vent system shall return
purged process fluid to the process line with no detectable volatile organic
material emissions to the atmosphere, or
2) A closed purge system or closed vent system shall collect and
recycle purged process fluid to the process line with no detectable volatile
organic material emissions to the atmosphere, or
3) Purged process fluid shall be transported to a control device
that complies with the requirements of Section 215.438.
d) In-situ sampling systems are exempt from subsection (c).