35 Ill. Adm. Code 212.185
Continuous Automatic Stoking Animal Pathological Waste Incinerators
Section 212
Section 212.185 Continuous
Automatic Stoking Animal Pathological Waste Incinerators
a) Section 212.181 of this Subpart shall not apply to continuous
automatic stoking pathological waste incinerators if all of the following
conditions are met:
1) The incinerator burns animal pathological waste exclusively,
except as otherwise prescribed by the Agency during specified test operation.
2) The incinerator burns no more than 907 kg/hr (2000 lbs/hr) of
waste.
3) The incinerator shall be multi-stage controlled air combustion
incinerator having cyclical pulsed stoking hearth.
b) No person shall cause or allow the emission of particulate
matter into the atmosphere from any continuous automatic stoking pathological
waste incinerator to exceed 1 gram of emission per 1 kg of animal pathological
waste charge (0.1 lb/100 lb).
c) The particulate matter emissions produced when burning animal
pathological waste using gaseous auxiliary fuel, such as natural gas, shall not
exceed the lbs/hr emission rate equivalent to the maximum concentration rate
set forth in Section 212.181(d) of this Subpart, when applied to burning a
maximum of 2000 lb of mixed charge animal pathological waste plus solid waste
for demonstration of compliance. "Mixed charge" shall contain no
more than 25 percent by weight of solid waste other than animal pathological
waste.