35 Ill. Adm. Code 212.446
Basic Oxygen Furnaces
Section 212
Section 212.446 Basic Oxygen
Furnaces
Emissions of particulate matter
from basic oxygen processes shall be controlled as follows:
a) Charging, Refining and Tapping. Particulate matter emissions
from all basic oxygen furnaces (BOF) shall be collected and ducted to pollution
control equipment. Unless subsection (c) of this Section applies, emissions
from basic oxygen furnace operations during the entire cycle (operations from
the beginning of the charging process through the end of the tapping process)
shall not exceed the allowable emission rate specified by Section 212.321 or
Section 212.322 of this Part, whichever is applicable. For purposes of
computing the process weight rate for this subsection, nongaseous material
charged to the furnace and process oxygen shall be included. No material shall
be included more than once.
b) Hot Metal Transfer, Hot Metal Desulfurization and Ladle Lancing.
1) Particulate matter emissions from hot metal transfers to a
mixer or ladle, hot metal desulfurization operations and ladle lancing shall be
collected and ducted to pollution control equipment, and emissions from the
pollution control equipment shall not exceed 69 mg/dscm (0.03 gr/dscf).
2) If the owner or operator can establish that the total
particulate matter emissions from hot metal transfers, hot metal
desulfurization operations and ladle lancing operations combined do not exceed
the allowable emissions as specified by Section 212.321 or Section 212.322,
whichever is applicable, where the process weight rate (P) is the hot metal
charged to the BOF vessel, then subsection (b)(1) above shall not apply.
c) No person shall cause or allow uncaptured emissions from any
opening in the building housing the BOF shop to exceed an opacity of 20 percent
at integrated iron and steel plants in the vicinity of Granite City, as
described in Section 212.324(a)(1)(C) of this Part. Compliance with this subsection
shall be determined in accordance with 40 CFR part 60, Appendix A, Method 9,
incorporated by reference in Section 212.113 of this Part, except that
compliance shall be determined by averaging any 12 consecutive observations
taken at 15 second intervals.