35 Ill. Adm. Code 215.102
Testing Methods
Section 215
Section 215.102 Testing
Methods
Volatile organic material or
organic material concentrations in a stream is measured by Method 18, 40 CFR
60, Appendix A, incorporated by reference in Section 215.105, Mearusrement of
Gaseous Organic Compounds incorporated by reference in 215.105 except as
follows. ASTM d‑4457, incorporated by reference in Section 215.105, may
be used for halogenated organic compounds. Method 25, 25A or 25B, 40 CFR 60,
Appendix A, incorporated by reference in 215.105 may be substituted for Method
18 provided the source owner or operator submits calibration data and other
proof that this method provides the information in the emission units of the
applicable standard. The volumetric flow rate and gas velocity is determined
in accordance with Methods 1, 1A, 2, 2A, 2C, 2D, 3 and 4, 40 CF Part 60,
Appendix A, incorporated by reference in 215.105. Any other alternate test
method must be approved by the Agency, which shall consider data comparing the
performance of the proposed alternative to the performance of the approved test
method(s). If the Agency determines that such data demonstrates that the
proposed alternative will achieve results equivalent to the approved test
method(s), the Agency shall approve the proposed alternative.