35 Ill. Adm. Code 215.421
General Requirements
Section 215
Section 215.421 General
Requirements
a) The owner or operator of a plant which has more than 1,500
components in gas or light liquid service, which components are used to
manufacture the synthetic organic chemicals or polymers listed in Appendix D,
shall conduct leak inspection and repair programs in accordance with this
Subpart for that component containing more than 10 percent volatile organic
material as determined by ASTM method E-260, E-168, and E-169, incorporated by
reference in Section 215.105. The provisions of this Subpart are not applicable
if the products listed in Appendix D are made from natural fatty acids for the
production of hexadecyl alcohol.
b) A component shall be considered to be leaking if the volatile
organic material concentration exceeds 10,000 parts per million ppm when
measured at a distance of 0 centimeters cm from the component as determined by
Method 21, 40 CFR Part 60, Appendix A, incorporated by reference in Section
215.105.