35 Ill. Adm. Code 215.437
Open-Ended Valves
Section 215
Section 215.437Â Open-Ended
Valves
a)Â Â Â Â Â Â Â Â Each open-ended valve shall be equipped with a cap, blind
flange, plug, or a second valve, except during operations requiring fluid flow
through the open-ended valve.
b)Â Â Â Â Â Â Â Â Each open-ended valve equipped with a second valve shall be
operated in a manner such that the valve on the process fluid end is closed
before the second valve is closed.
c)Â Â Â Â Â Â Â Â Components which are open-ended valves and which serve as a
sampling connection shall be controlled such that:
1)Â Â Â Â Â Â Â Â A closed purge system or closed vent system shall return
purged process fluid to the process line with no detectable volatile organic
material emissions to the atmosphere, or
2)Â Â Â Â Â Â Â Â A closed purge system or closed vent system shall collect and
recycle purged process fluid to the process line with no detectable volatile
organic material emissions to the atmosphere, or
3)Â Â Â Â Â Â Â Â Purged process fluid shall be transported to a control device
that complies with the requirements of Section 215.438.
d)Â Â Â Â Â Â Â Â In-situ sampling systems are exempt from subsection (c).