35 Ill. Adm. Code 215.481
Control of Reactors, Distillation Units, Crystallizers, Centrifuges and Vacuum Dryers
Section 215
Section 215.481Â Control of
Reactors, Distillation Units, Crystallizers, Centrifuges and Vacuum Dryers
a)Â Â Â Â Â Â Â Â The owner or operator shall control all reactors, distillation
units, crystallizers, centrifuges and vacuum dryers that are used to
manufacture pharmaceuticals with surface condensers or other air pollution
control equipment listed in subsection (a)(2).
1)Â Â Â Â Â Â Â Â If a surface condenser is used, it shall be operated such that
the condenser outlet gas temperature does not exceed:
A)Â Â Â Â Â Â Â 248.2 K (-13 F) when condensing volatile organic material of
vapor pressure greater than 40.0 kPa (5.8 psi) at 294.3 K (70 F); or
B)Â Â Â Â Â Â Â 258.2 K (5 F) when condensing volatile organic material of
vapor pressure greater than 20.0 kPa (2.9 psi) at 294.3 K (70 F); or
C)Â Â Â Â Â Â Â 273.2 K (32 F) when condensing volatile organic material of
vapor pressure greater than 10.0 kPa (1.5 psi) at 294.3 K (70 F); or
D)Â Â Â Â Â Â Â 283.2 K (50 F) when condensing volatile organic material of
vapor pressure greater than 7.0 kPa (1.0 psi) at 294.3 K (70 F); or
E)Â Â Â Â Â Â Â 298.2 K (77 F) when condensing volatile organic material of
vapor pressure greater than 3.45 kPa (0.5 psi) at 294.3 K (70 F).
2)Â Â Â Â Â Â Â Â If a scrubber, carbon adsorber, thermal incinerator, catalytic
incinerator or other air pollution control equipment other than a surface
condenser is used, such equipment shall provide a reduction in the emissions of
volatile organic material of 90 percent or more.
b)Â Â Â Â Â Â Â Â The owner or operator shall enclose all centrifuges used to
manufacture pharmaceuticals and that have an exposed volatile organic liquid
surface, where the volatile organic material in the volatile organic liquid has
a vapor pressure of 3.45 kPa (0.5 psi) or more at 294.3 K (70 F), except as
production, sampling, maintenance or inspection procedures require operator
access.