35 Ill. Adm. Code 215.525
Emission Limitations for Air Oxidation Processes
Section 215
Section 215.525Â Emission
Limitations for Air Oxidation Processes
a)Â Â Â Â Â Â Â Â No person shall cause or allow the emission of volatile
organic material (VOM) from any process vent stream unless the process vent
stream is vented to a combustion device which is designed and operated
either:
1)Â Â Â Â Â Â Â Â To reduce the volatile organic emissions vented to it with an
efficiency of at least ninety eight percent (98%) by weight; or
2)Â Â Â Â Â Â Â Â To emit volatile organic material at a concentration less than
twenty parts per million by volume, dry basis.
b)Â Â Â Â Â Â Â Â Air oxidation facilities for which an existing combustion
device is employed to control process VOM emissions are not required to meet
the 98 percent emissions limit until the combustion device is replaced for
other reasons, which shall be considered to include, but not be limited to,
normal maintenance, malfunction, accident, and obsolescence. The combustion
device is considered to be replaced when:
1)Â Â Â Â Â Â Â Â All of the device is replaced; or
2)Â Â Â Â Â Â Â Â When the cost of the repair of the device or the cost of
replacement of part of the device exceeds 50% of the cost of replacing the
entire device with a device which complies.
c)Â Â Â Â Â Â Â Â The limitations of subsection (a) do not apply to any process
vent stream or combination of process vent streams which has a Total Resource
Effectiveness Index (TRE) greater than 1.0, as determined by the following
methods:
1)Â Â Â Â Â Â Â Â If an air oxidation process has more than one process vent
stream, TRE shall be based upon a combination of the process vent stream.
2)Â Â Â Â Â Â Â Â TRE of a process vent stream shall be determined according to
the following equation:
TRE
=
E
-1
[a + bF
n
+ cF + dFH + e(FH)
n
+ fF
0.5
]
where:
n
=
0.88
TRE
=
Total resource effectiveness
index.
F
=
Vent stream flowrate
(scm/min), at a standard temperature of 20 C.
E
=
Hourly measured emissions in
kg/hr.
H
=
Net heating value of the vent
stream (MJ/scm), where the net enthalpy per mole of offgas is based on
combustion at 25 C and 760 mm Hg, but the standard temperature for
determining the volume corresponding to one mole is 20 C, as in the
definition of "Flow".
a,b,c,d,
e and f
=
Coefficients obtained by use
of Appendix F.
3)Â Â Â Â Â Â Â Â For nonchlorinated process vent streams, if the net heating
value, H, is greater than 3.6 MJ/scm, F shall be replaced by F' for purposes of
calculating TRE. F' is computed as follows:
F'
=
FH / 3.6
where f and H
are as defined in subsection (c)(2).
4)Â Â Â Â Â Â Â Â The actual numerical values used in the equation described in
subsection (c)(2) shall be determined as follows:
A)Â Â Â Â Â Â Â All reference methods and procedures for determining the flow,
(F), hourly emissions, (E), and net heating, (H), value shall be in accordance
with Appendix E.
B)Â Â Â Â Â Â Â All coefficients described in subsection (c)(2) shall be in
accordance with Appendix F.