35 Ill. Adm. Code 216.361
Petroleum and Petrochemical Processes
Section 216
Section 216.361 Petroleum
and Petrochemical Processes
a) A person must not cause or allow the emission of a carbon
monoxide waste gas stream into the atmosphere from a petroleum or petrochemical
process unless the waste gas stream is burned in a direct flame afterburner or
carbon monoxide boiler so that the resulting concentration of carbon monoxide
in the waste gas stream is less than or equal to 200 ppm corrected to 50
percent excess air, or the waste gas stream is controlled by other equivalent
air pollution control equipment approved by the Agency under 35 Ill. Adm. Code
201.
b) Regardless of subsection (a), any existing petroleum or
petrochemical process using catalyst regenerators of fluidized catalytic
converters equipped for in situ combustion of carbon monoxide may emit a carbon
monoxide waste gas stream into the atmosphere if the carbon monoxide
concentration of the waste gas stream is less than or equal to 750 ppm
corrected to 50 percent excess air.
c) Regardless of subsection (a), any new petroleum or
petrochemical process using catalyst regenerators of fluidized catalytic
converters equipped for in situ combustion of carbon monoxide may emit a carbon
monoxide waste gas stream into the atmosphere if the carbon monoxide
concentration of the waste gas stream is less than or equal to 350 ppm
corrected to 50 percent excess air.
d) For
the petroleum refinery facilities located in Channahon, Lemont, and Robinson
Illinois, regardless of subsections (a) through (c), during startup and hot
standby, petroleum catalytic cracking units must comply either with subsections
(a) through (c) or the non-numerical standards for these operating modes in 40
CFR 63 Subpart UUU Tables 9, 10, 14, and 41, 40 CFR 63.1565(a)(5), 40 CFR
63.1570(c) and (f), 40 CFR 63.1572(c), and 40 CFR 63.1576(a)(2) and (d),
incorporated by reference in Section 216.104.