35 Ill. Adm. Code 217.244
Emissions Limitations
Section 217.244 Emissions Limitations
a) On
and after January 1, 2015, no person shall cause or allow emissions of NO
x
into the atmosphere from any reheat furnace, annealing furnace, or
galvanizing furnace used in iron and steel making to exceed the following
limitations. Until July 1, 2025, compliance must be demonstrated with the
applicable emissions limitation on an ozone season and annual basis. On and
after July 1, 2025, compliance must be demonstrated with the applicable
emissions limitation on a 30-day rolling average basis.
Emission Unit Type
NO
x
Emissions Limitation (lb/mmBtu) Before July 1, 2025
Reheat furnace, regenerative
0.18
Reheat furnace, recuperative,
combusting natural gas
0.09
Reheat furnace, recuperative,
combusting a combination of natural gas and coke oven gas
0.142
Reheat furnace, cold-air
0.03
Annealing furnace,
regenerative
0.38
Annealing furnace,
recuperative
0.16
Annealing furnace, cold-air
0.07
Galvanizing furnace,
regenerative
0.46
Galvanizing furnace,
recuperative
0.16
Galvanizing furnace, cold air
0.06
Emission Unit Type
NO
x
Emissions Limitation (lb/mmBtu) On and after July 1, 2025
Reheat furnace, cold air
0.03
Reheat
furnace, regenerative and recuperative
0.09
Annealing furnace, cold air
0.07
Annealing furnace,
regenerative and recuperative
0.08
Galvanizing furnace, cold air
0.06
Galvanizing furnace,
regenerative and recuperative
0.08
b) On
and after January 1, 2015, no person shall cause or allow emissions of NO
x
into the atmosphere from any reverberatory furnace or crucible furnace used in
aluminum melting to exceed the following limitations. Until July 1, 2025,
compliance must be demonstrated with the applicable emissions limitation on an
ozone season and annual basis. On and after July 1, 2025, compliance must be
demonstrated with the applicable emissions limitation on a 30-day rolling
average basis.
Emission Unit Type
NO
x
Emissions Limitation (lb/mmBtu)
Reverberatory furnace
0.08
Crucible furnace
0.16