35 Ill. Adm. Code 2190.219.435
Recordkeeping and Reporting Requirements
Section 219
TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE B: AIR POLLUTION
CHAPTER I: POLLUTION CONTROL BOARD
SUBCHAPTER c: EMISSIONS STANDARDS AND LIMITATIONS FOR STATIONARY SOURCES
PART 219 ORGANIC MATERIAL EMISSION STANDARDS AND LIMITATIONS FOR THE METRO EAST AREA
SECTION 219.435 RECORDKEEPING AND REPORTING REQUIREMENTS
Section 219.435
Recordkeeping and Reporting Requirements
a) Every owner or operator of a reactor or distillation unit with
a TRE index value of 4.0 or less shall keep records, for a minimum of 3 years,
of the following parameters measured during a performance test or TRE
determination required under Section 219.433 of this Subpart, and required to
be monitored under Section 219.434 of this Subpart.
1) Every owner or operator of a source that seeks to demonstrate
compliance with Section 219.432(a)(1) of this Subpart through the use of either
a thermal or catalytic incinerator shall maintain records of the following:
A) The average firebox temperature of the incinerator (or the
average temperature upstream and downstream of the catalyst bed for a catalytic
incinerator), measured at least every 15 minutes and averaged over the same
time period of the performance testing; and
B) The percent reduction of VOM determined as specified in Section
219.433(c) of this Subpart achieved by the incinerator, or the concentration of
VOM (ppmv, by compound) determined as specified in Section 219.433(c) of this
Subpart at the outlet of the control device, on a dry basis, corrected to 3
percent oxygen.
2) Every owner or operator of a source that seeks to demonstrate
compliance with Section 219.432(a)(1) of this Subpart through the use of a
boiler or process heater shall maintain the records described below. Any
boiler or process heater in which all vent streams are introduced with primary
fuel are exempt from these requirements.
A) A description of the location at which the vent stream is
introduced into the boiler or process heater; and
B) The average combustion temperature of the boiler or process
heater with a design heat input capacity of less than 44 megawatt measured at
least every 15 minutes and averaged over the same time period of the
performance testing.
3) Every owner or operator of a source that seeks to demonstrate
compliance with Section 219.432(a)(2) of this Subpart through use of a
smokeless flare, or flare design (i.e., steam-assisted, air-assisted, or
nonassisted) shall maintain records of all visible emission readings, heat
content determinations, flow rate measurements, and exit velocity
determinations made during the performance test, continuous records of the
flare pilot flame monitoring, and records of all periods of operations during
which the pilot flame is absent.
4) Every owner or operator of a source that seeks to demonstrate
compliance with Section 219.432(b) of this Subpart shall maintain records of
the following:
A) Where an absorber is the final recovery device in the recovery
system, the exit specific gravity (or alternative parameter) which is a measure
of the degree of absorbing liquid saturation, if approved by the Agency and
USEPA, and average exit temperature of the absorbing liquid measured at least
every 15 minutes and averaged over the same time period as the performance
testing (both measured while the vent stream is normally routed and
constituted);
B) Where a condenser is the final recovery device in the recovery
system, the average exit (product side) temperature measured at least every 15
minutes and averaged over the same time period as the performance testing while
the vent stream is normally routed and constituted;
C) Where a carbon absorber is the final recovery device in the
recovery system, the total steam mass or volumetric flow measured at least
every 15 minutes and averaged over the same time period as the performance
testing (full carbon bed cycle), the temperature of the carbon bed after regeneration
(and within 15 minutes of completion of any cooling cycle(s)), and duration of
the carbon bed steaming cycle (all measured while the vent stream is normally
routed and constituted);
D) As an alternative to subsection (a)(4)(A), (a)(4)(B) or (a)(4)(C)
of this Section, the concentration level or reading indicated by the organic
monitoring device at the outlet of the absorber, condenser, or carbon absorber,
measured at least every 15 minutes and averaged over the same time period as
the performance testing (measured while the vent stream is normally routed and
constituted); or
E) All measurements and calculations performed to determine the
flow rate, VOM concentration, heating value, and TRE index value of the vent
stream.
b) Every owner or operator of a reactor or distillation unit with
a TRE index value of less than 4.0 shall be subject to the exceedance reporting
requirements of the draft Enhanced Monitoring Guidelines as published at 58
Fed. Reg. 54648 (October 22, 1993).
c) Every owner or operator of a source seeking to comply with
Section 219.432(b) of this Subpart shall maintain records of the following:
1) Any changes in production capacity, feedstock type, catalyst
type, or of any replacement, removal, or addition of recovery equipment or
reactors and distillation units; and
2) Any recalculation of the flow rate, VOM concentration, or TRE
index value calculated according to subsection (c) of Appendix G of this Part.
d) Every owner or operator of a source claiming a design capacity
of less than 1 gigagram (1,100 tons) per year, as contained in Section
219.431(b) of this Subpart, shall maintain records of the design capacity or
any changes in equipment or operations that may affect the design capacity.
e) Every owner or operator of a source claiming a vent stream
flow rate or vent stream concentration exemption level, as contained in Section
219.431(b)(5) of this Subpart, shall maintain records to indicate that the
stream flow rate is less than 0.0085 scm/min or the vent stream concentration
is less than 500 ppmv.