35 Ill. Adm. Code 217.860
Recordkeeping
Section 217
Section 217.860
Recordkeeping
a) The owner or operator of an emission reduction source shall
keep and maintain the following records for each NO
x
emission unit
at the source subject to the NO
x
emission cap:
1) Daily, monthly, and control period operating hours;
2) Type and quantity of each fuel used daily during the control
period;
3) Control period capacity factor of individual fuels fired and
all fuels fired;
4) Monitoring records; and
5) To the extent applicable, the performance test data from the
initial performance test for each emission reduction unit and the performance
evaluation for each CEMS using the applicable performance specifications in 40
CFR 60, Appendix B, as incorporated by reference in Section 217.104 of this
Part.
b) The owner or operator of an emission reduction source shall
maintain records of the following information for each operating day for each
NO
x
emission unit subject to the NO
x
emission cap:
1) Calendar date;
2) The average hourly NO
x
mass emission rate expressed
as lbs/hr;
3) The control period total NO
x
mass emissions to date;
4) Identification of times when emission data have been excluded
from the calculation of NO
x
mass emissions, the reasons for excluding
the data, and any corrective actions taken;
5) Identification of the times when the pollutant concentration
exceeded full span of the CEMS;
6) Description of any modifications to the CEMS that could affect
the ability of the CEMS to comply with the Performance Specifications in 40 CFR
60, Appendix B; and
7) Results of daily CEMS drift tests and quarterly accuracy
assessments as required under 40 CFR 60, Appendix F.
c) The owner or operator of any NO
x
emission reduction
source subject to the continuous monitoring requirements for NO
x
under
this Subpart, shall submit a compliance certification containing the
information recorded under subsection (b) of this Section. All compliance
certification reports shall be postmarked by November 1 or the next business
day if November 1 falls on a Saturday or Sunday, of each control period in
which NO
x
emission reductions are generated.
d) Maintenance of records: Unless otherwise provided, the owner
or operator of a NO
x
emission reduction source shall be kept on site
at the source, each of the following documents for a period of 5 years from the
date the document is created. This period may be extended for cause, at any
time prior to the end of 5 years, in writing by the Agency.
1) The emission reduction proposal and all documents that
demonstrate the accuracy of the statements in the proposal for each year the
emission reduction source generates NO
x
reductions under this Subpart
and for 5 years thereafter.
2) All emissions monitoring information required pursuant to this
Subpart; provided that to the extent that 40 CFR 60 provides for a 3-year
period for recordkeeping, the 3-year period shall apply.
3) Copies of all reports, compliance certifications, and other
submissions and all records made or required under this Subpart.
4) Copies of all documents used to complete any permit
application and supporting documents and any other submission to demonstrate
compliance with the requirements of this Subpart.