35 Ill. Adm. Code 219.182
Cold Cleaning
Section 219
Section 219.182 Cold
Cleaning
a) Operating Procedures: No person shall operate a cold cleaning
degreaser unless:
1) Waste solvent is stored in covered containers only and not
disposed of in such a manner that more than 20% of the waste solvent (by
weight) is allowed to evaporate into the atmosphere;
2) The cover of the degreaser is closed when parts are not being
handled; and
3) Parts are drained until dripping ceases.
b) Equipment Requirements: No person shall operate a cold
cleaning degreaser unless:
1) The degreaser is equipped with a cover which is closed
whenever parts are not being handled in the cleaner. The cover shall be
designed to be easily operated with one hand or with the mechanical assistance
of springs, counter-weights or a powered system if:
A) The solvent vapor pressure is greater than 2 kPa (15 mmHg or
0.3 psi) measured at 38° C (100° F);
B) The solvent is agitated; or
C) The solvent is heated above ambient room temperature.
2) The degreaser is equipped with a device for draining cleaned
parts. The drainage device shall be constructed so that parts are enclosed
under the cover while draining unless:
A) The solvent vapor pressure is less than 4.3 kPa (32 mmHg or 0.6
psi) measured at 38° C (100°F); or
B) An internal drainage device cannot be fitted into the cleaning
system, in which case the drainage device may be external.
3) The degreaser is equipped with one of the following control
devices if the vapor pressure of the solvent is greater than 4.3 kPa (32 mmHg
or 0.6 psi) measured at 38° C (100° F) or if the solvent is heated above 50° C
(120° F) or its boiling point:
A) A freeboard height of
7
/
10
of the inside
width of the tank or 91 cm (36 in), whichever is less; or
B) Any other equipment or system of equivalent emission control as
approved by the Agency and further processed consistent with Section 219.108 of
this Part. Such a system may include a water cover, refrigerated chiller or
carbon adsorber.
4) A permanent conspicuous label summarizing the operating
procedure is affixed to the degreaser; and
5) If a solvent spray is used, the degreaser is equipped with a
solid fluid stream spray, rather than a fine, atomized or shower spray.
c) Material and Control Requirements:
1) On and after March 15, 1999, no person shall:
A) Cause or allow the sale of solvent with a vapor pressure which
exceeds 2.0 mmHg (0.038 psi) measured at 20° C (68° F) in units greater than
five gallons, for use in cold cleaning degreasing operations located in the
area covered by Section 219.103 of this Part.
B) Operate a cold cleaning degreaser with a solvent vapor pressure
which exceeds 2.0 mmHg (0.038 psi) measured at 20° C (68° F).
2) On and after March 15, 2001, no person shall:
A) Cause or allow the sale of solvent with a vapor pressure which
exceeds 1.0 mmHg (0.019 psi) measured at 20° C (68° F) in units greater than
five gallons, for use in cold cleaning degreasing operations located in the
area covered by Section 219.103 of this Part.
B) Operate a cold cleaning degreaser with a solvent vapor pressure
which exceeds 1.0 mmHg (0.019 psi) measured at 20° C (68° F).
3) On and after May 30, 2007, no person shall:
A) Cause or allow the sale of solvent with a vapor
pressure which exceeds 1.0 mmHg (0.019 psi) measured at 20° C (68° F) in units
greater than five gallons, for use in cold cleaning degreasing operations
located in the area covered by Section 219.103 of this Part, unless the
purchaser provides a copy of a valid State or federal construction or operating
permit or a copy of the Federal Register demonstrating that the purchaser is in
compliance with the control requirements of subsection (c)(4) of this Section or
is exempt under subsection (f) or (g) of this Section.
B) Operate
a cold cleaning degreaser with a solvent vapor pressure which exceeds 1.0 mmHg
(0.019 psi) measured at 20° C (68° F), unless the person is in compliance with
the control requirements of subsection (c)(4) of this Section or is exempt
under subsection (f) or (g) of this Section.
4) Control Requirements:
A) A person may operate a cold cleaning degreaser
using solvent with a vapor pressure greater than 1.0 mmHg (0.019 psi) but less
than 56 mmHg (1.064 psi) measured at 20° C (68° F) provided add-on control
devices demonstrating at least 95 percent overall capture and control of
emissions are used. The add-on controls may include, but are not limited to,
carbon adsorbers or afterburners.
B) An equivalent alternative control plan may be
used to meet the control requirements of this Section pursuant to Section
219.108 of this Part. Pursuant to the material requirements of subsection
(c)(3)(B) of this Section, a solvent with a vapor pressure of 1.0 mmHg (0.019
psi) measured at 20° C (68° F) shall be the basis for assessment of equivalent
emissions from any equivalent alternative control plan. If used as an
equivalent alternative control plan, an add-on control must demonstrate at
least a 95 percent overall capture and control efficiency. A control plan
approved by the Agency shall be effective only when included in a federally
enforceable permit or approved by the USEPA as a SIP revision pursuant to
Section 219.108 of this Part.
C) Add-on controls operating at a source prior to May
30, 2007, shall be tested by August 31, 2007. Add-on controls constructed on
or after May 30, 2007, shall be tested within 90 days after initial startup.
Testing procedures and recordkeeping for add-on controls and equivalent
alternative controls subject to subsections (c)(4)(A) and (B) of this Section
are to be performed pursuant to Section 219.105(c), (d), (e) and (f) of this
Part
.
d) Recordkeeping and Reporting Requirements: On and after March
15, 1999:
1) All persons subject to the requirements of subsections
(c)(1)(A), (c)(2)(A), and (c)(3)(A) of this Section must maintain records which
include for each sale:
A) The name and address of the solvent purchaser;
B) The date of sale;
C) The type of solvent;
D) The unit volume of solvent;
E) The total volume of solvent; and
F) The vapor pressure of the solvent measured in mmHg at 20° C
(68° F).
2) All persons subject to the requirements of subsections
(c)(1)(B), (c)(2)(B), and (c)(3)(B) of this Section must maintain records which
include for each purchase:
A) The name and address of the solvent supplier;
B) The date of purchase;
C) The type of solvent;
D) The vapor pressure of the solvent measured in mmHg at 20° C (68°
F); and
E) For any mixture of solvents, the vapor pressure
of the mixture, as used, measured in mmHg at 20° C (68° F).
3) All persons subject to the requirements of
subsection (c)(4) of this Section must maintain records, which include for each
purchase:
A) The
name and address of the solvent supplier;
B) The
date of purchase;
C) The
type of solvent;
D) The unit volume of solvent;
E) The
total volume of solvent;
F) The vapor pressure of the solvent measured in
mmHg at 20° C (68° F); and
G) For any mixture of solvents, the vapor pressure
of the mixture, as used, measured in mmHg at 20° C (68° F).
4) All persons subject to the requirements of
subsection (c)(4) of this Section shall maintain records documenting the use of
good operating practices consistent with the equipment manufacturer's
specifications for the cold cleaning degreasers and add-on control equipment.
At a minimum these records shall include:
A) Records for periodic inspection of the cold
cleaning degreasers and add-on control equipment with date of inspection,
individual performing the inspection, and nature of inspection;
B) Records for repair of malfunctions and breakdowns
with identification and description of incident, date identified, date
repaired, nature of repair, and the amount of VOM that escaped into the
atmosphere as a result of the incident;
C) Control device monitoring and recording data; and
D) A daily log of operating time for the control
device, monitoring equipment, and all associated degreasers.
5) All persons subject to the requirements of
subsection (c) of this Section shall notify the Agency at least 30 days before
changing the method of compliance between subsection (c)(3) and (c)(4) of this
Section. Such notification shall include a demonstration of compliance with
the newly applicable subsection.
6) All persons subject to the requirements of
subsection (b) or (c) of this Section shall notify the Agency of any violation
of subsection (b) or (c) of this Section by sending a description of the
violation and copies of records documenting such violations to the Agency
within 30 days following the occurrence of the violation.
e) All records required by subsection (d) of this Section shall
be retained for three years and shall be made available to the Agency upon
request.
f) The cleaning of electronic components as defined in 35 Ill.
Adm. Code Section 211.1885 is exempt from the requirements of subsection (c) of
this Section.
g) Any cold cleaning taking place in a Detrex cold batch
degreaser Model #2D-CC-SPL Size 24-4-10, or substantial equivalent, including
automated loading of parts, totally enclosed operation (excluding loading and unloading)
and permitted by the Agency, is exempt from the requirements of subsection (c)
of this Section.