35 Ill. Adm. Code 218.120
Control Requirements for Storage Containers of VOL
Section 218
Section 218.120Â Control
Requirements for Storage Containers of VOL
a)Â Â Â Â Â Â Â Â Every owner or operator storing VOL in a vessel of 40,000
gallons or greater with a maximum true vapor pressure equal to 0.75 psia but
less than 11.1 psia shall reduce VOM emissions from storage tanks, reservoirs,
or other containers as follows:
1)Â Â Â Â Â Â Â Â Each fixed roof tank shall be equipped with an internal
floating roof that meets the following specifications or that is equipped with
a vapor control system that meets the specifications contained in subsection
(a)(4) below:
A)Â Â Â Â Â Â Â The internal floating roof shall rest or float on the liquid
surface (but not necessarily in complete contact with it) inside a storage
vessel that has a fixed roof. The internal floating roof shall be floating on
the liquid surface at all times, except during initial fill and during those
intervals when the storage vessel is completely emptied and subsequently
refilled. When the roof is resting on the leg supports, the process of
filling, emptying, or refilling shall be continuous and shall be accomplished
as rapidly as possible.
B)Â Â Â Â Â Â Â Each internal floating roof shall be equipped with one of the
following closure devices between the wall of the storage vessel and the edge
of the internal floating roof:
i)Â Â Â Â Â Â Â Â Â A foam- or liquid-filled seal mounted in contact with the
liquid (liquid-mounted seal). A liquid-mounted seal means a foam- or
liquid-filled seal mounted in contact with the liquid between the wall of the
storage vessel and the floating roof continuously around the circumference of
the tank;
ii)Â Â Â Â Â Â Â Â Two seals mounted one above the other so that each forms a
continuous closure that completely covers the space between the wall of the
storage vessel and the edge of the internal floating roof. The lower seal may
be vapor-mounted, but both must be continuous; or
iii)Â Â Â Â Â Â Â A mechanical shoe seal, which is a metal sheet held
vertically against the wall of the storage vessel by springs or weighted levers
and is connected by braces to the floating roof. A flexible coated fabric
(envelope) spans the annular space between the metal sheet and the floating
roof.
C)Â Â Â Â Â Â Â Each opening in a noncontact internal floating roof except for
automatic bleeder vents (vacuum breaker vents) and the rim space vents is to
provide a projection below the liquid surface.
D)Â Â Â Â Â Â Â Each opening in the internal floating roof except for leg
sleeves, automatic bleeder vents, rim space vents, column wells, ladder wells,
sample wells, and stub drains is to be equipped with a cover or lid which is
to be maintained in a closed position at all times (i.e., no visible gap)
except when the device is in actual use. The cover or lid shall be equipped
with a gasket. Covers on each access hatch and automatic gauge float well shall
be bolted except when they are in use.
E)Â Â Â Â Â Â Â Automatic bleeder vents shall be equipped with a gasket and are
to be closed at all times when the roof is floating except when the roof is
being floated off or is being landed on the roof leg supports.
F)Â Â Â Â Â Â Â Â Rim space vents shall be equipped with a gasket and are to be
set to open only when the internal floating roof is not floating or at the
manufacturer's recommended setting.
G)Â Â Â Â Â Â Â Each penetration of the internal floating roof for the purpose
of sampling shall be a sample well. The sample well shall have a slit fabric
cover that covers at least 90 percent of the opening.
H)Â Â Â Â Â Â Â Each penetration of the internal floating roof that allows for
passage of a ladder shall have a gasketed sliding cover.
2)Â Â Â Â Â Â Â Â During the next scheduled tank cleaning or before March 15,
2004, whichever comes first, each internal floating roof tank shall meet the
specifications set forth in subsections (a)(1)(A) through (H) above.
3)Â Â Â Â Â Â Â Â Each external floating roof tank shall meet the following
specifications:
A)Â Â Â Â Â Â Â Each external floating roof shall be equipped with a closure
device between the wall of the storage vessel and the roof edge. The closure
device is to consist of two seals, one above the other. The lower seal is
referred to as the primary seal, and the upper seal is referred to as the
secondary seal.
i)Â Â Â Â Â Â Â Â Â Except as provided in Section 218.127(b)(4) of this Subpart,
the primary seal shall completely cover the annular space between the edge of
the floating roof and tank wall and shall be either a liquid mounted seal or a
shoe seal.
ii)Â Â Â Â Â Â Â Â The secondary seal shall completely cover the annular space
between the external floating roof and the wall of the storage vessel in a
continuous fashion except as allowed in Section 218.127(b)(4) of this Subpart.
iii)Â Â Â Â Â Â Â The tank shall be equipped with the closure device after the
next scheduled tank cleaning, but no later than March 15, 2004.
B)Â Â Â Â Â Â Â Except for automatic bleeder vents and rim space vents, each
opening in a noncontact external floating roof shall provide a projection below
the liquid surface. Except for automatic bleeder vents, rim space vents, roof
drains, and leg sleeves, each opening in the roof is to be equipped with a
gasketed cover, seal, or lid that is to be maintained in a closed position at
all times (i.e., no visible gap) except when the device is in actual use.Â
Automatic bleeder vents are to be closed at all times when the roof is floating
except when the roof is being floated off or is being landed on the roof leg
supports. Rim vents are to be set to open when the roof is being floated off the
roof leg supports or at the manufacturer's recommended setting. Automatic
bleeder vents and rim space vents are to be gasketed. Each emergency roof
drain is to be provided with a slotted membrane fabric cover that covers at
least 90 percent of the area of the opening.
C)Â Â Â Â Â Â Â The roof shall be floating on the liquid at all times (i.e.,
off the roof leg supports) except when the tank is completely emptied and
subsequently refilled. The process of filling, emptying, or refilling when the
roof is resting on the leg supports shall be continuous and shall be
accomplished as rapidly as possible.
4)Â Â Â Â Â Â Â Â A closed vent system and control device respectively shall
meet the following specifications:
A)Â Â Â Â Â Â Â The closed vent system shall be designed to collect all VOM
vapors and gases discharged from the storage vessel and operated with no
detectable emissions as indicated by an instrument reading of less than 500 ppm
above background and visual inspections, as determined by the methods specified
in 40 CFR 60.485(c), incorporated by reference at Section 218.112(d) of this
Part.
B)Â Â Â Â Â Â Â The control device shall be designed and operated to reduce
inlet VOM emissions by 95 percent or greater. If a flare is used as the
control device, it shall meet the specifications described in the general
control device requirements of 40 CFR 60.18, incorporated by reference at
Section 218.112(d) of this Part.
5)Â Â Â Â Â Â Â Â An alternative emission control plan equivalent to the
requirements of subsection (a)(1), (a)(2), (a)(3), or (a)(4) above that has
been approved by the Agency and the USEPA in a federally enforceable permit or
as a SIP revision.
b)Â Â Â Â Â Â Â Â The owner or operator of each storage vessel with a design
capacity equal to or greater than 40,000 gallons which contains VOL that, as
stored, has a maximum true vapor pressure greater than or equal to 11.1 psia
shall equip each storage vessel with a closed vent system and control device as
specified in subsection (a)(4) above.
c)Â Â Â Â Â Â Â Â Notwithstanding subsection (b) of this Section, where anÂ
owner or operator can demonstrate that the control device installed on a
storage vessel on or before December 31, 1992, was designed to reduce inlet VOM
emissions by greater than or equal to 90 percent but less than 95 percent, the
control device shall be operated to reduce inlet VOM emission by 90 percent or
greater.