35 Ill. Adm. Code 218.431
Applicability
Section 218
Section 218.431
Applicability
a) The provisions of Sections 218.431 through 218.436 of this
Subpart shall apply to:
1) Every owner or operator of any chemical manufacturing process
unit that manufactures, as a primary product, one or more of the chemicals
listed in Appendix A of this Part and that chemical manufacturing process unit
causes or allows any reactor or distillation unit, either individually or in
tandem, to discharge one or more process vent streams either directly to the
atmosphere or to a recovery system; and
2) All continuous distillation and reactor process emission units
not subject to Section 218.520 through 218.527 of this Part, and located within
Stepan Company's Millsdale manufacturing facility, Elwood, Illinois.
b) Notwithstanding subsection (a) of this Section, the control
requirements set forth within Section 218.432 of this Subpart shall not apply
to the following:
1) Any process vent stream with a total resource effectiveness
(TRE) index value greater than 1.0. However, such process vent stream remains
subject to the performance testing requirements contained in Section 218.433 of
this Subpart and the reporting and recordkeeping requirements contained in
Section 218.435 of this Subpart;
2) Any reactor or distillation unit that is designed and operated
as a batch operation;
3) Any reactor or distillation unit that is part of a polymer
manufacturing operation;
4) Any reactor or distillation unit that is part of the chemical
manufacturing process unit with a total design capacity of less than 1 gigagram
(1,100 tons) per year for all chemicals produced, as a primary product, within
that process unit. However, such operations remain subject to the reporting and
recordkeeping requirements contained in Section 218.435(d) of this Subpart;
5) Any vent stream with a flow rate less than 0.0085 scm/min or a
total VOM concentration of less than 500 ppmv, less methane and ethane, as
measured by Method 18, or a concentration of VOM of less than 250 ppmv as
measured by Method 25A. However, such operations remain subject to the
performance testing requirement listed in Section 218.433 of this Subpart, as well
as the reporting and recordkeeping requirements contained in Section 218.435 of
this Subpart; or
6) Any reactor or distillation unit included within an Early
Reduction Program, as specified in 40 CFR 63, and published in 57 Fed. Reg.
61970 (December 29, 1992), evidenced by a timely enforceable commitment
approved by USEPA.