35 Ill. Adm. Code 218.501
Control Requirements for Batch Operations
Section 218
Section 218.501 Control
Requirements for Batch Operations
a) Every owner or operator of a single unit operation with an
average flow rate, as determined in accordance with Section 218.502(b) of this
Subpart, below the flow rate value calculated by the applicability equations
contained in Section 218.500(e) of this Subpart, shall reduce uncontrolled VOM
emissions from such single unit operation by an overall efficiency, on average,
of at least 90 percent, or 20 ppmv, per batch cycle.
b) Every owner or operator of a batch process train with an
average flow rate, as determined in accordance with Section 218.502(b)(2) of
this Subpart, below the flow rate value calculated by the applicability
equations contained in Section 218.500(e) of this Subpart, shall reduce
uncontrolled VOM emissions from such batch process train by an overall
efficiency, on average, of at least 90 percent, or 20 ppmv, per batch cycle.
For purposes of demonstrating compliance with the emission limitations set
forth in this Section, any control device meeting the criteria in subsection
(c) of this Section shall be deemed to achieve a control efficiency of 90
percent, or 20 ppmv, per batch cycle, as applicable.
c) Notwithstanding subsections (a) or (b) of this Section, any
source that has installed on or before March 15, 1995, any control device which
is demonstrated to the Agency's satisfaction to be unable to meet the
applicable control requirements of this Section, scrubber, or shell and tube
condenser using a non-refrigerated cooling media, and such device achieves at
least 81 percent control efficiency of VOM emissions, is required to meet the
90 percent emission limitation or 20 ppmv VOM concentration set forth in
subsections (a) or (b) of this Section, as applicable, upon the earlier to
occur of the date the device is replaced for any reason, including, but not
limited to, normal maintenance, malfunction, accident, and obsolescence, or
December 31, 1999. A scrubber, shell and tube condenser using a
non-refrigerated cooling media, or other control device meeting the criteria of
this subsection, is considered replaced when:
1) All of the device is replaced; or
2) When either the cost to repair the device or the cost to
replace part of the device exceeds 50 percent of the cost of replacing the
entire device with a control device that complies with the 90 percent emission
limitation or 20 ppmv VOM concentration level in subsection (a) of this
Section, as applicable.
d) If a boiler or process heater is used to comply with this
Section, the vent stream shall be introduced into the flame zone of the boiler
or process heater.
e) If a flare is used to comply with this Section, it shall
comply with the requirements of 40 CFR 60.18, incorporated by reference at
Section 218.112 of this Part. The flare operation requirements of 40 CFR 60.18
do not apply if a process, not subject to this Subpart, vents an emergency
relief discharge into a common flare header and causes the flare servicing the
process subject to this Subpart to not comply with one or more of the
provisions of 40 CFR 60.18.