35 Ill. Adm. Code 225.535
Methodology for Calculating Ozone Season Allocations
Section 225.535 Methodology for Calculating Ozone Season
Allocations
The Agency will calculate converted gross electrical output (CGO),
in MWh, for each CAIR NO
x
Ozone Season unit that has operated during
at least one control period prior to the calendar year in which the Agency
reports the allocations to USEPA as follows:
a) For
control periods 2009, 2010, and 2011, the owner or operator of the unit must
submit in writing to the Agency, by September 15, 2007, a statement that either
gross electrical output data or heat input data is to be used to calculate
converted gross electrical output. The data shall be used to calculate
converted gross electrical output pursuant to either subsection (a)(1) or
(a)(2) of this Section:
1) Gross
electrical output: If the unit has four or five control periods of data, then
the gross electrical output (GO) will be the average of the unit's three
highest gross electrical outputs from the 2001, 2002, 2003, 2004, or 2005
control periods. If the unit has three or fewer control periods of gross
electrical outputs, the gross electrical output will be the average of those
control periods for which data is available. If a generator is served by two
or more units, then the gross electrical output of the generator will be
attributed to each unit in proportion to the unit's share of the total control
period heat input of these units for the control period. The unit's converted
gross electrical output will be calculated as follows:
A) If the
unit is coal-fired:
CGO (in MWh) = GO
(in MWh)
´
1.0;
B) If the
unit is oil-fired:
CGO (in MWh) = GO
(in MWh)
´
0.6; or
C) If the
unit is neither coal-fired nor oil-fired:
CGO (in MWh) = GO
(in MWh)
´
0.4.
2) Heat
input (HI): If the unit has four or five control periods of data, the average
of the unit's three highest control period heat inputs from 2001, 2002, 2003,
2004, or 2005 will be used. If the unit has three or fewer control periods of heat
input data, the heat input will be the average of those control periods for
which data is available. The unit's converted gross electrical output will be
calculated as follows:
A) If the
unit is coal-fired:
CGO (in MWh) = HI
(in mmBtu)
´
0.0967;
B) If the
unit is oil-fired:
CGO (in MWh) = HI
(in mmBtu)
´
0.0580; or
C) If the
unit is neither coal-fired nor oil-fired:
CGO (in MWh) = HI
(in mmBtu)
´
0.0387.
b) For
control periods 2012 and 2013, the owner or operator of the unit must submit in
writing to the Agency, by June 1, 2008, a statement that either gross
electrical output data or heat input data is to be used to calculate the unit's
converted gross electrical output. The unit's converted gross electrical
output shall be calculated pursuant to either subsection (b)(1) or (b)(2) of
this Section:
1) Gross
electrical output: The average of the unit's two most recent years of control
period gross electrical output, if available. If a unit commences commercial
operation in the 2007 control period and does not have gross electrical output
for the 2006 control period, the gross electrical output from the 2007 control
period will be used. If a generator is served by two or more units, the gross
electrical output of the generator shall be attributed to each unit in
proportion to the unit's share of the total control period heat input of such
units for the control period. The unit's converted gross electrical output
shall be calculated as follows:
A) If the
unit is coal-fired:
CGO (in MWh) = GO
(in MWh)
´
1.0;
B) If the
unit is oil-fired:
CGO (in MWh) = GO
(in MWh)
´
0.6;
C) If the
unit is neither coal-fired nor oil-fired:
CGO (in MWh) = GO
(in MWh)
´
0.4.
2) Heat
input: The average of the unit's two most recent years of control period heat
inputs, e.g., for the 2012 control period, the average of the unit's heat input
from the 2006 and 2007 control periods. The unit's converted gross electrical
output shall be calculated as follows:
A) If the
unit is coal-fired:
CGO (in MWh) = HI
(in mmBtu)
´
0.0967;
B) If the
unit is oil-fired:
CGO (in MWh) = HI
(in mmBtu)
´
0.0580; or
C) If the
unit is neither coal-fired nor oil-fired:
CGO (in MWh) = HI
(in mmBtu)
´
0.0387.
c) For
control period 2014 and thereafter, the unit's gross electrical output will be
the average of the unit's two most recent control period's gross electrical
output, if available. If a unit commences commercial operation in the most
recent control period and does not have gross electrical output from the most
recent control period, e.g., if the unit commences commercial operation in the
2009 control period and does not have gross electrical output from the 2008
control period, gross electrical output from the 2009 control period will be
used. If a generator is served by two or more units, the gross electrical
output of the generator will be attributed to each unit in proportion to the
unit's share of the total control period heat input of these units for the
control period. The unit's converted gross electrical output will be calculated
as follows:
1) If
the unit is coal-fired:
CGO (in MWh) = GO
(in MWh)
´
1.0;
2) If the
unit is oil-fired:
CGO (in MWh) = GO
(in MWh)
´
0.6; or
3) If the
unit is neither coal-fired nor oil-fired:
CGO (in MWh) = GO
(in MWh)
´
0.4.
d) For a
unit that is a combustion turbine or boiler and has equipment used to produce
electricity and useful thermal energy for industrial, commercial, heating, or
cooling purposes through the sequential use of energy, the Agency will add the
converted gross electrical output calculated for electricity pursuant to
subsection (a), (b), or (c) of this Section to the converted useful thermal
energy (CUTE) to determine the total converted gross electrical output for the
unit (TCGO). The Agency will determine the converted useful thermal energy by
using the average of the unit's control period useful thermal energy for the
prior two control periods, if available. In the first control period for which
the unit is considered to be an existing unit rather than a new unit, the unit's
control period useful thermal output for the prior year will be used. The
converted useful thermal energy will be determined using the following
equations:
1) If the
unit is coal-fired:
CUTE (in MWh) =
UTE (in mmBtu)
´
0.2930;
2) If the
unit is oil-fired:
CUTE (in MWh) =
UTE (in mmBtu)
´
0.1758; or
3) If the
unit is neither coal-fired nor oil-fired:
CUTE (in MWh) =
UTE (in mmBtu)
´
0.1172.
e) The
CAIR NO
x
Ozone Season unit's converted gross electrical output and converted
useful thermal energy in subsections (a)(1), (b)(1), (c), and (d) of this
Section for each control period will be based on the best available data
reported or available to the Agency for the CAIR NO
x
Ozone Season
unit pursuant to the provisions of Section 225.550.
f) The
CAIR NO
x
Ozone Season unit's heat input in subsections (a)(2) and
(b)(2) of this Section for each control period will be determined in accordance
with 40 CFR 75, as incorporated by reference in Section 225.140.