35 Ill. Adm. Code 219.410
Monitoring Requirements for Lithographic Printing
Section 219
Section 219.410 Monitoring
Requirements for Lithographic Printing
a) Fountain Solution Temperature
1) The owner or operator of any lithographic printing lines relying
on the temperature of the fountain solution to demonstrate compliance shall
install, maintain, and continuously operate a temperature monitor of the
fountain solution in the reservoir or fountain tray, as applicable.
2) The temperature monitor must be capable of reading with an
accuracy of 1°C or 2°F, and must be attached to an automatic, continuous
recording device such as a strip chart, recorder, or computer, with at least
the same accuracy, that is installed, calibrated and maintained in accordance
with the manufacturer's specifications. If the automatic, continuous recording
device malfunctions, the owner or operator shall record the temperature of the
fountain solution at least once every two operating hours. The automatic,
continuous recording device shall be repaired or replaced as soon as
practicable.
b) Fountain Solution VOM Content. The owner or operator of any
lithographic printing lines subject to Section 219.407(a)(1)(A), (a)(2) or
(a)(3) of this Subpart shall:
1) For a fountain solution to which VOM is not added
automatically:
A) Maintain records of the VOM content of the fountain solution in
accordance with Section 219.411(e)(2)(C); or
B) Take a sample of the as-applied fountain solution from the
fountain tray or reservoir, as applicable, each time a fresh batch of fountain
solution is prepared or each time VOM is added to an existing batch of fountain
solution in the fountain tray or reservoir, and shall determine compliance with
the VOM content limitation of the as-applied fountain solution by using one of
the following options:
i) With a refractometer or hydrometer with a visual, analog, or
digital readout and with an accuracy of 0.5 percent. The refractometer or
hydrometer must be calibrated with a standard solution for the type of VOM used
in the fountain solution, in accordance with manufacturer's specifications,
against measurements performed to determine compliance. The refractometer or
hydrometer must be corrected for temperature at least once per 8-hour shift or
once per batch of fountain solution prepared or modified, whichever is longer;
or
ii) With a conductivity meter if it is demonstrated that a
refractometer and hydrometer cannot distinguish between compliant and
noncompliant fountain solution for the type and amount of VOM in the fountain
solution. A source may use a conductivity meter if it demonstrates that both
hydrometers and refractometers fail to provide significantly different
measurements for standard solutions containing 95 percent, 100 percent and 105
percent of the applicable VOM content limit. The conductivity meter reading for
the fountain solution must be referenced to the conductivity of the incoming
water. A standard solution shall be used to calibrate the conductivity meter
for the type of VOM used in the fountain solution, in accordance with
manufacturer's specifications;
2) For fountain solutions to which VOM is added at the source
with automatic feed equipment, determine the VOM content of the as-applied
fountain solution based on the setting of the automatic feed equipment which
makes additions of VOM up to a pre-set level. Records must be retained of the
VOM content of the fountain solution in accordance with Section 219.411(e)(2)(D)
of this Subpart. The equipment used to make automatic additions must be
installed, calibrated, operated and maintained in accordance with
manufacturer's specifications.
c) Afterburners for Heatset Web Offset Lithographic Printing
Lines.
If an
afterburner is used to demonstrate compliance, the owner or operator of a
heatset web offset lithographic printing line subject to Section 219.407(a)(1)(C)
of this Subpart shall:
1) Install, calibrate, maintain, and operate temperature
monitoring devices with an accuracy of 3°C or 5F° on the afterburner in
accordance with Section 219.105(d)(2) of this Part and in accordance with the
manufacturer's specifications. Monitoring shall be performed at all times when
the afterburner is operating; and
2) Install, calibrate, operate and maintain, in accordance with
manufacturer's specifications, a continuous recorder on the temperature
monitoring devices, such as a strip chart, recorder or computer, with at least
the same accuracy as the temperature monitor.
d) Other Control Devices for Heatset Web Offset Lithographic
Printing Lines. If a control device other than an afterburner is used to
demonstrate compliance, the owner or operator of a heatset web offset
lithographic printing line subject to this Subpart shall install, maintain,
calibrate and operate such monitoring equipment as set forth in the owner or
operator's plan approved by the Agency and USEPA pursuant to Section 219.407(b)
of this Subpart.
e) Cleaning Solution
1) The owner or operator of any lithographic printing line
relying on the VOM content of the cleaning solution to comply with Section
219.407(a)(4)(A) of this Subpart must:
A) For cleaning solutions that are prepared at the source with
equipment that automatically mixes cleaning solvent and water (or other
non-VOM):
i) Install, operate, maintain, and calibrate the automatic feed
equipment in accordance with manufacturer's specifications to regulate the
volume of each of the cleaning solvent and water (or other non-VOM), as mixed;
and
ii) Pre-set the automatic feed equipment so that the consumption
rates of the cleaning solvent and water (or other non-VOM), as applied, comply with
Section 219.407(a)(4)(A) of this Subpart;
B) For cleaning solutions that are not prepared at the source with
automatic feed equipment, keep records of the usage of cleaning solvent and
water (or other non-VOM) as set forth in Section 219.411(f)(2) of this Subpart.
2) The owner or operator of any lithographic printing line
relying on the vapor pressure of the cleaning solution to comply with Section
219.407(a)(4)(B) of this Subpart must keep records for such cleaning solutions
used on any such lines as set forth in Section 219.411(f)(2)(C) of this
Subpart.