35 Ill. Adm. Code 219.488

Monitoring for Air Pollution Control Equipment

Year: 2026Length: 109 wordsOfficial source
Section 219 Section 219.488  Monitoring for Air Pollution Control Equipment a)         At a minimum, continuous monitors for the following parameters shall be installed on air pollution control equipment used to control sources subject to this Subpart: 1)         Destruction device combustion temperature. 2)         Temperature rise across a catalytic afterburner bed. 3)         VOM concentration on a carbon adsorption unit to determine breakthrough. 4)         Outlet gas temperature of a refrigerated condenser. 5)         Temperature of a non-refrigerated condenser coolant supply system. b)         Each monitor shall be equipped with a recording device. c)         Each monitor shall be calibrated quarterly. d)         Each monitor shall operate at all times while the associated control equipment is operating.