35 Ill. Adm. Code 219.892
Testing and Monitoring Requirements
Section 219.892 Testing and Monitoring Requirements
a) Testing
to demonstrate compliance with the requirements of Section 219.891 of this
Subpart shall be conducted by the owner or operator by May 1, 2012.
Thereafter, testing shall be conducted within 90 days after a request by the
Agency, or as otherwise specified in this Subpart. The testing shall be
conducted at the expense of the owner or operator and the owner or operator
shall notify the Agency in writing 30 days in advance of conducting the testing
to allow the Agency to be present during testing.
b) Testing
to demonstrate compliance with the monomer VOM content limitations for resin
and gel coat materials in Section 219.891(b) of this Subpart shall be conducted
upon request of the Agency, or as otherwise specified in this Subpart, in
accordance with SCAQMD 312-91, incorporated by reference in Section 219.112 of
this Part.
c) The
owner or operator of a source complying with this Subpart pursuant to Section
219.891(d) shall comply with the following:
1) By
May 1, 2012, or upon initial start-up, whichever is later, and upon start-up of
a new control device, conduct an initial performance test of the control device
in accordance with this subsection (c) that demonstrates compliance with the
emission limitation determined pursuant to Section 219.891(d).
2) Subsequent
to the initial performance test described in subsection (c)(1) of this Section,
conduct at least one performance test per calendar year. Performance tests
used to demonstrate compliance with Section 219.891(d) shall be conducted at
least six months apart, unless the performance test is being conducted
following an exceedance of operating parameters as described in subsection
(c)(3) of this Section, or per a request by the Agency.
3) Monitor
and record relevant operating parameters, including the control efficiency of
the control device and the amount of materials used in the fiberglass boat
manufacturing process, during each control device performance test used to
demonstrate compliance with Section 219.891(d). The owner or operator shall continue
to operate the fiberglass boat manufacturing process within the parameters
until another performance test is conducted that demonstrates compliance with
Section 219.891(d). The owner or operator shall monitor the parameters at all
times when the control device is in operation. If the fiberglass boat
manufacturing process exceeds any operating parameter by more than 10 percent,
the owner or operator shall conduct additional performance testing in
accordance with this Section within 10 operating days after the exceedance;
4) The
methods and procedures of Section 219.105(d) and (f) shall be used for testing
to demonstrate compliance with the requirements of Section 219.891(d) of this
Subpart, as follows:
A) To
select the sampling sites, Method 1 or 1A, as appropriate, 40 CFR
60, appendix A, incorporated by reference at Section 219.112 of this Part. The
sampling sites for determining efficiency in reducing VOM from the dryer
exhaust shall be located between the dryer exhaust and the control device
inlet, and between the outlet of the control device and the exhaust to the
atmosphere;
B) To
determine the volumetric flow rate of the exhaust stream, Method 2, 2A, 2C, or
2D, as appropriate, 40 CFR 60, appendix A, incorporated by reference at Section
219.112 of this Part;
C) To
determine the VOM concentration of the exhaust stream entering and exiting the
control device, Method 25 or 25A, as appropriate, 40 CFR 60, appendix A,
incorporated by reference at Section 219.112 of this Part. For thermal and catalytic
afterburners, Method 25 must be used except under the following circumstances,
in which case Method 25A must be used:
i) The
allowable outlet concentration of VOM from the control device is less than 50
ppmv, as carbon;
ii) The
VOM concentration at the inlet of the control device and the required level of
control result in exhaust concentrations of VOM of 50 ppmv, or less, as carbon;
and
iii) Due
to the high efficiency of the control device, the anticipated VOM concentration
at the control device exhaust is 50 ppmv or less, as carbon, regardless of
inlet concentration. If the source elects to use Method 25A under this option,
the exhaust VOM concentration must be 50 ppmv or less, as carbon, and the
required destruction efficiency must be met for the source to have demonstrated
compliance. If the Method 25A test results show that the required destruction
efficiency apparently has been met, but the exhaust concentration is above 50
ppmv, as carbon, a retest is required. The retest shall be conducted using
either Method 25 or 25A. If the retest is conducted using Method 25A and the
test results again show that the required destruction efficiency apparently has
been met, but the exhaust concentration is above 50 ppmv, as carbon, the source
must retest again using Method 25.
D) Notwithstanding
the criteria or requirements in Method 25, which specifies a minimum probe
temperature of 129
°
C (265
°
F), the probe must be heated to at least the
gas stream temperature of the dryer exhaust, typically close to 176.7
°
C (350
°
F);
and
E) During
testing, the fiberglass boat manufacturing operation shall be operated at
representative operating conditions and flow rates.
5) If an
afterburner is used to demonstrate compliance, the owner or operator shall:
A) Install,
calibrate, operate, and maintain temperature monitoring devices with an
accuracy of 3
°
C or 5
°
F on the emissions control system in
accordance with Section 219.105(d)(2) of this Part and in accordance with the
manufacturer's specifications. Monitoring shall be performed at all times when
the emissions control system is operating; and
B) Install,
calibrate, operate and maintain, in accordance with manufacturer's
specifications, a continuous recorder on the temperature monitoring devices,
such as a strip chart, recorder or computer, with at least the same accuracy as
the temperature monitor.
6) If a
carbon adsorber is used to demonstrate compliance, the owner or operator shall
use Agency and USEPA approved continuous monitoring equipment that is
installed, calibrated, maintained, and operated according to vendor
specifications at all times the control device is in use. The continuous
monitoring equipment shall monitor the VOM concentration of each carbon
adsorption bed exhaust or the exhaust of the bed next in sequence to be
desorbed.
7) If an
emissions control system other than an afterburner or carbon adsorber is used
to demonstrate compliance, the owner or operator shall install, maintain,
calibrate, and operate the monitoring equipment as set forth in the owner's or
operator's plan approved by the Agency and USEPA pursuant to Section
219.891(d).
d) Testing
to demonstrate compliance with the VOM content limitations for cleaning
solutions in Section 219.891(g) of this Subpart, and with the non-monomer VOM
content limitations for resin and gel coat materials in Section 219.891(a) of
this Subpart, shall be conducted upon request of the Agency, or as otherwise
specified in this Subpart, as follows:
1) The
applicable test methods and procedures specified in Section 219.105(a) of this
Part shall be used; provided, however, Method 24, incorporated by reference at
Section 219.112 of this Part, shall be used to demonstrate compliance; or
2) For
cleaning solvents, the manufacturer's specifications for VOM content may be
used if the manufacturer's specifications are based on results of tests of the
VOM content conducted in accordance with methods specified in Section
219.105(a) of this Part; provided, however, Method 24 shall be used to determine
compliance. In the event of any inconsistency between a Method 24 test and the
manufacturer's specifications, the Method 24 test shall govern.
e) The
owner or operator of a source subject to this Subpart and relying on the VOM
content of the cleaning solution to comply with Section 219.891(g)(1) of this
Subpart shall:
1) For
cleaning solutions that are prepared at the source with equipment that
automatically mixes cleaning solvent and water (or other non-VOM):
A) Install,
operate, maintain, and calibrate the automatic feed equipment in accordance
with manufacturer's specifications to regulate the volume of each of the
cleaning solvent and water (or other non-VOM), as mixed; and
B) Pre-set
the automatic feed equipment so that the consumption rates of the cleaning
solvent and water (or other non-VOM), as applied, comply with Section
219.891(g)(1);
2) For
cleaning solutions that are not prepared at the source with automatic feed
equipment, keep records of the usage of cleaning solvent and water (or other
non-VOM) as set forth in Section 219.894(g) of this Subpart.
f) Testing
to demonstrate compliance with the VOM composite partial vapor pressure
limitation for cleaning solvents set forth in Section 219.891(g) of this
Subpart shall be conducted in accordance with the applicable methods and
procedures set forth in Section 219.110 of this Part.