35 Ill. Adm. Code 219.903
Monitoring Requirements
Section 219.903 Monitoring Requirements
a) If an
afterburner is used to demonstrate compliance, the owner or operator of a
source subject to Section 219.901(d) of this Subpart shall:
1) Install,
calibrate, operate, and maintain temperature monitoring devices with an
accuracy of 3
°
C or 5
°
F on the emissions control system in
accordance with Section 219.105(d)(2) of this Part and in accordance with the
manufacturer's specifications. Monitoring shall be performed at all times when
the emissions control system is operating; and
2) Install,
calibrate, operate and maintain, in accordance with manufacturer's
specifications, a continuous recorder on the temperature monitoring devices,
such as a strip chart, recorder or computer, with at least the same accuracy as
the temperature monitor.
b) If a
carbon adsorber is used to demonstrate compliance, the owner or operator of a
source subject to Section 219.901(d) of this Subpart shall use Agency and USEPA
approved continuous monitoring equipment that is installed, calibrated,
maintained, and operated according to vendor specifications at all times the
control device is in use. The continuous monitoring equipment shall monitor
the VOM concentration of each carbon adsorption bed exhaust or the exhaust of the
bed next in sequence to be desorbed.
c) If an
emissions control system other than an afterburner or carbon adsorber is used
to demonstrate compliance, the owner or operator of a source subject to Section
219.901(d) of this Subpart shall install, maintain, calibrate, and operate the monitoring
equipment as set forth in the owner's or operator's plan approved by the Agency
and USEPA pursuant to Section 219.901(d)(3).