35 Ill. Adm. Code 219.APPENDIX C
C Reference Methods and Procedures
Section 219
Section 219.APPENDIX C Reference
Methods and Procedures
Introduction
This Appendix presents the
reference methods and procedures required for implementing Reasonably Available
Control Technology (RACT). Methods and procedures are identified for two types
of RACT implementation:
a) Determination of VOM destruction efficiency for evaluating
compliance with the 98 weight percent VOM reduction or 20 ppmv emission limit
specified in Sections 219.520 through 219.527 of this Part; and
b) Determination of offgas flowrate, hourly emissions and stream
net heating value for calculating TRE.
All reference methods identified
in this Appendix refer to the reference methods specified at 40 CFR 60,
Appendix A, incorporated by reference in Section 219.112 of this Part.
VOM
DESTRUCTION EFFICIENCY DETERMINATION
The following reference methods
and procedures are required for determining compliance with the percent
destruction efficiency specified in Sections 219.520 through 219.527 of this
Part.
a) Reference Method 1 or 1A for selection of the sampling site.
The control device inlet sampling site for determination of vent stream molar
composition or total organic compound destruction efficiency shall be prior to
the inlet of any control device and after all recovery devices.
b) Reference Methods 2, 2A, 2C or 2D for determination of the
volumetric flowrate.
c) Reference Method 3 to measure oxygen concentration of the air
dilution correction. The emission sample shall be corrected to 3 percent
oxygen.
d) Reference Method 18 to determine the concentration of total
organic compounds (minus methane and ethane) in the control device outlet and
total organic compound reduction efficiency of the control device.
TRE DETERMINATION
The following reference methods
and procedures are required for determining the offgas flowrate, hourly
emissions, and the net heating value of the gas combusted to calculate the vent
stream TRE.
a) Reference Method 1 or 1A for selection of the sampling site.
The sampling site for the vent stream flowrate and molar composition
determination prescribed in (b) and (c) shall be prior to the inlet of any
combustion device, prior to any post-reactor dilution of the stream with air
and prior to any post-reactor introduction of halogenated compounds into the
vent stream. Subject to the preceding restrictions on the sampling site, it
shall be after the final recovery device. If any gas stream other than the air
oxidation vent stream is normally conducted through the recovery system of the
affected facility, such stream shall be rerouted or turned off while the vent
stream is sampled, but shall be routed normally prior to the measuring of the
initial value of the monitored parameters for determining compliance with the
recommended RACT. If the air oxidation vent stream is normally routed through
any equipment which is not a part of the air oxidation process as defined in 35
Ill. Adm. Code 211.350, such equipment shall be bypassed by the vent stream
while the vent stream is sampled, but shall not be bypassed during the
measurement of the initial value of the monitored parameters for determining
compliance with Subpart V.
b) The molar composition of the vent stream shall be determined
using the following methods:
1) Reference Method 18 to measure the concentration of all
organics, including those containing halogens, unless a significant portion of
the compounds of interest are polymeric (high molecular weight), can polymerize
before analysis or have low vapor pressures, in which case Reference Method
25(a) shall be used.
2) ASTM D1946-67 (reapproved 1977), incorporated by reference in
Section 219.112 of this Part, to measure the concentration of carbon monoxide
and hydrogen.
3) Reference Method 4 to measure the content of water vapor, if
necessary.
c) The volumetric flowrate shall be determined using Reference
Method 2, 2A, 2C or 2D, as appropriate.
d) The net heating value of the vent stream shall be calculated
using the following equation:
where:
H
=
Net heating value of the
sample, MJ/scm, where the net enthalpy per mole of offgas is based on
combustion at 25°C and 760 mm Hg, but the standard temperature for
determining the volume corresponding to one mole is 20°C, as in the
definition of F (vent stream flowrate) below
K
=
Constant, 1.740 x 10
-7
(1/ppm) (mole/scm) (MJ/kal) where standard temperature for mole/scm is 20°C
C
i
=
Concentration of sample
component i, reported on a wet basis, in ppm, as measured by Reference Method
18 or ASTM D1946-67 (reapproved 1977), incorporated by reference in Section
219.112 of this Part.
H
i
=
Net heat of combustion of
sample component i, kcal/mole based on combustion at 25°C and 760 mm Hg. If published
values are not available or cannot be calculated, the heats of combustion of
vent stream components are required to be determined using ASTM D2382-76,
incorporated by reference in Section 219.112 of this Part.
e) The emission rate of total organic compounds in the process
vent stream shall be calculated using the following equation:
where:
E
=
Emission rate of total organic
compounds (minus methane and ethane) in the sample in kg/hr;
K
=
Constant, 2.494 x 10
-6
(1/ppm) (mole/scm) (kg/g) (min/hr), where standard temperature for mole/scm
is 20°C;
M
i
=
Molecular weight of sample
component i (g/mole);
F
=
Vent stream flowrate
(scm/min), at a standard temperature of 20°C
f) The total vent stream concentration (by volume) of compounds
containing halogens (ppmv, by compound) shall be summed from the individual
concentrations of compounds containing halogens which were measured by
Reference Method 18.