35 Ill. Adm. Code 220.290
Recordkeeping Requirements
Section 220
Section 220.290
Recordkeeping Requirements
Each owner or operator of an MSW
landfill shall keep for at least 5 years, unless another time period is
specified in this Section, up-to-date, readily accessible, on-site records of
the following:
a) For the life of the landfill, the design capacity report in
which the landfill became equal to or greater than 2.5 million Mg and 2.5
million m
3
, the current amount of solid waste in-place, and the
year-by-year waste acceptance rate. Off-site records may be maintained if they
are retrievable within 4 hours. Either paper copy or electronic formats are
acceptable.
b) For the life of the control equipment, the data listed in
subsections (b)(1) through (b)(4) of this Section as measured during the
initial performance test or compliance determination. Records of the control
device vendor specifications shall be maintained until removal.
1) Active collection systems:
A) The maximum expected gas generation flow rate as calculated in
Section 220.240(a) of this Subpart. The owner or operator may use another method
to determine the maximum gas generation flow rate, if the method has been
approved by the Agency.
B) The density of wells, horizontal collectors, surface
collectors, or other gas extraction devices determined using the procedures
specified in Section 220.220(b)(1)(A) of this Subpart.
2) Enclosed combustion device other than a boiler or process
heater with a design heat input capacity greater 44 MW:
A) The combustion temperature measured at least every 15 minutes
and averaged over the same time period as the performance test.
B) The percent reduction of NMOC determined as specified in
Section 220.230(b) of this Subpart achieved by the control device.
3) Boilers or process heaters of any size: a description of the
location at which the collected gas vent stream is introduced into the boiler
or process heater over the same time period as the performance testing.
4) Open flare: the flare type (i.e., steam-assisted,
air-assisted, or nonassisted), all visible emission readings, heat content
determination, flow rate or bypass flow rate measurements, and exit velocity
determinations made during the performance test as specified in 40 CFR 60.18,
incorporated by reference in Section 220.130 of this Part; continuous records
of the flare pilot flame or flare flame monitoring and records of all periods
of operations during which the flare pilot flame or the flare flame is absent.
c) Continuous records of the equipment operating parameters
specified to be monitored in Section 220.270 of this Subpart as well as
up-to-date, readily accessible records for periods of operation during which
the parameter boundaries established during the most recent performance test
are exceeded.
1) The following constitute exceedences that shall be recorded
and reported under Section 220.280(e) of this Subpart:
A) For enclosed combustors, except for boilers and process heaters
with design heat input of 44 MW (150 mmbtu/hr) or greater, all 3-hour periods
of operation during which the average combustion temperature was more than 28°C
(82°F) below the average combustion temperature during the most recent
performance test at which compliance with Section 220.230(b) of this Subpart
was determined.
B) For boilers or process heaters, whenever there is a change in
the location at which the vent stream is introduced into the flame zone, as
required pursuant to subsection (b)(2)(A) of this Section.
2) Continuous records of the indication of flow to the control
device or the indication of bypass flow or records of monthly inspections of
car-seals or lock-and-key configurations used to seal bypass lines, specified
pursuant to Section 220.270 of this Subpart.
3) For boilers or process heaters with a design heat input
capacity of 44 MW or greater, records of all periods of operation of boiler or
process heater. (Examples of such records include records of steam use, fuel
use, or monitoring data collected pursuant to State, local, or federal regulatory
requirements.)
4) For open flares, records of the flame or flare pilot flame
monitoring specified under Section 220.270(c) of this Subpart, and all periods
of operation in which the flare pilot flame or the flare flame is absent.
d) For the life of the collection system, a plot map showing each
existing and planned collector in the system and providing a unique
identification location label for each collector, including:
1) The location of all newly installed collectors as specified
under Section 220.240(b) of this Part.
2) The nature, date of deposition, amount, and location of
asbestos-containing or nondegradable waste excluded from collection, as
provided in Section 220.220(b)(1)(D)(i) of this Subpart, as well as any
nonproductive areas excluded from collection, as provided in Section
220.220(b)(1)(D)(ii) of this Subpart.
e) All collection and control system exceedences of the
operational standards in Section 220.250 of this Subpart, the reading the
subsequent month whether or not the second reading is an exceedence, and the
location of each exceedence.
f) Owners or operators who convert design capacity from volume to
mass or mass to volume to demonstrate that landfill design capacity is less
than 2.5 million Mg or 2.5 million m
3
, as provided in the definition
of "design capacity", shall keep records of the annual recalculation
of site-specific density, design capacity, and the supporting documentation.