35 Ill. Adm. Code 223.310
Standards
Section 223.310 Standards
a) VOM
Content Limits: Except as provided in subsection (c), no person shall
manufacture, blend, or repackage for sale within Illinois, supply, sell, or
offer for sale within Illinois, or solicit for application or apply within
Illinois, any architectural coating manufactured on or after July 1, 2009 that
contains a VOM content in excess of the corresponding limit specified below:
VOM Content Limit
Grams/Liter
(Pounds/Gallon)
Coating Category
1)
Flat Coatings
100
(0.8)
2)
Non-Flat Coatings
150
(1.3)
3)
Non-Flat High-Gloss Coatings
250
(2.1)
Specialty Coatings
4)
Antenna Coatings
530
(4.4)
5)
Antifouling Coatings
400
(3.3)
6)
Bituminous Roof Coatings
300
(2.5)
7)
Bituminous Roof Primers
350
(2.9)
8)
Bond Breakers
350
(2.9)
9)
Calcamine Recoaters
475
(4.0)
10)
Clear Wood Coatings
A)
Clear Brushing Lacquers
680
(5.7)
B)
Lacquers
(including lacquer sanding sealers)
550
(4.6)
C)
Sanding Sealers
(other than lacquer sanding sealers)
350
(2.9)
D)
Varnishes
350
(2.9)
11)
Concrete Curing Compounds
350
(2.9)
Concrete Surface Retarder
780
(6.5)
12)
Conversion Varnish
725
(6.0)
13)
Dry Fog Coatings
400
(3.3)
14)
Faux Finishing Coatings
350
(2.9)
15)
Fire-Resistive Coatings
350
(2.9)
16)
Fire-Retardant Coatings
A)
Clear
650
(5.4)
B)
Opaque
350
(2.9)
17)
Floor Coatings
250
(2.1)
18)
Flow Coatings
420
(3.5)
19)
Form-Release Compounds
250
(2.1)
20)
Graphic Arts Coatings (Sign Paints)
500
(4.2)
21)
High-Temperature Coatings
420
(3.5)
22)
Impacted Immersion Coating
780
(6.5)
23)
Industrial Maintenance Coatings
340
(2.8)
24)
Low-Solids Coatings
120
(1.0)
25)
Magnesite Cement Coatings
450
(3.8)
26)
Mastic Texture Coatings
300
(2.5)
27)
Metallic Pigmented Coatings
500
(4.2)
28)
Multi-Color Coatings
250
(2.1)
29)
Nuclear Coating
450
(3.8)
30)
Pre-Treatment Wash Primers
420
(3.5)
31)
Primers, Sealers, and Undercoaters
200
(1.7)
32)
Quick-Dry Enamels
250
(2.1)
33)
Quick-Dry Primers, Sealers and Undercoaters
200
(1.7)
34)
Recycled Coatings
250
(2.1)
35)
Roof Coatings
250
(2.1)
36)
Rust Preventive Coatings
400
(3.3)
37)
Shellacs
A)
Clear
730
(6.1)
B)
Opaque
550
(4.6)
38)
Specialty Primers, Sealers, and Undercoaters
350
(2.9)
39)
Stains
250
(2.1)
40)
Stone Consolidants
450
(3.8)
41)
Swimming Pool Coatings
340
(2.8)
42)
Swimming Pool Repair and Maintenance Coatings
340
(2.8)
43)
Temperature-Indicator Safety Coatings
550
(4.6)
44)
Thermoplastic Rubber Coatings and Mastics
550
(4.6)
45)
Traffic Marking Coatings
150
(1.3)
46)
Waterproofing Concrete/Masonry Sealers
400
(3.3)
47)
Waterproofing Sealers
250
(2.1)
48)
Wood Preservatives
350
(2.9)
BOARD NOTE: Conversion factor:
one pound VOM per gallon (U.S.) = 119.95 grams per liter.
b) Limits
are expressed in grams of VOM per liter of coating thinned to the manufacturer's
maximum recommendation, excluding the volume of any water, exempt compounds, or
colorant added to tint bases. "Manufacturers maximum recommendation"
means the maximum recommendation for thinning that is indicated on the label or
lid of the coating container.
c) Most
Restrictive VOM Limit. If anywhere on the container of any architectural
coating, or any label or sticker affixed to the container, or in any sales,
advertising, or technical literature supplied by a manufacturer or anyone
acting on the manufacturer's behalf, any representation is made that indicates
that the coating meets the definition of or is recommended for use for more than
one of the coating categories listed in subsection (a), then the most
restrictive VOM content limit shall apply. This provision does not apply to
the coating categories specified in subsections (c)(1) through (c)(21):
1) Lacquer coatings (including
lacquer sanding sealers);
2) Metallic pigmented
coatings;
3) Shellacs;
4) Fire-retardant
coatings;
5) Pretreatment wash
primers;
6) Industrial maintenance
coatings;
7) Low-solids coatings;
8) Wood preservatives;
9) High-temperature
coatings;
10) Temperature-indicator
safety coatings;
11) Antenna
coatings;
12) Antifouling
coatings;
13) Flow
coatings;
14) Bituminous
roof primers;
15) Specialty
primers, sealers, and undercoaters;
16) Conversion
varnish;
17) Calcimine
recoaters;
18) Impacted
immersion coatings;
19) Nuclear
coatings;
20) Thermoplastic
rubber coating and mastics;
21) Concrete
surface retarder.
d) Painting
Practices. All architectural coating containers used to apply their contents
to a surface directly from the container by pouring, siphoning, brushing,
rolling, padding, ragging, or other means shall be closed when not in use.
These architectural coatings containers include, but are not limited to, drums,
buckets, cans, pails, trays, or other application containers. Containers of
any VOM-containing materials used for thinning and cleanup shall also be closed
when not in use.
e) Thinning.
No person who applies or solicits the application of any architectural coating
shall apply a coating that is thinned to exceed the applicable VOM limit
specified in subsection (a).
f) Rust
Preventive Coatings. No person shall apply or solicit the application of any
rust preventive coating for industrial use unless the rust preventive coating
complies with the industrial maintenance coating VOM limit specified in subsection
(a). If the coating is also regulated under another Part, the more restrictive
limit shall apply.
g) Coatings
Not Listed in Subsection (a). For any coating that does not meet any of the
definitions for the specialty coatings categories listed in subsection (a), the
VOM content limit shall be determined by classifying the coating as a flat
coating, a non-flat coating, or a non-flat high-gloss coating, based on its
gloss, as defined in Section 223.307, and the corresponding flat or non-flat
coating limit shall apply.