35 Ill. Adm. Code 226.155
Total Enclosure
Section 226.155 Total Enclosure
a) An
owner or operator of a lead emission unit subject to this Part must install,
maintain, and operate one or more total enclosures to minimize fugitive
emissions from the operations listed in subsections (a)(1) through (6) at all
times that the applicable lead emission unit in the total enclosure is
operating or housekeeping activities are being performed. The total enclosure
must meet the requirements specified in subsections (b) through (e).
1) Battery
breaking areas.
2) Dryer
and dryer areas, including transition pieces, charging hoppers, chutes, and
skip hoists conveying any lead-containing material.
3) Reverberatory
furnaces or rotary furnaces charging any lead-containing material and the
associated reverberatory furnace areas or rotary furnace areas, including any
associated lead taps, slag taps, and molds during processing.
4) Alloying
and refining kettles and associated areas, including any associated lead taps,
slag taps, and molds during processing.
5) Areas
where dross, dust from fabric filters, sweepings, or used fabric filters are
handled, except for areas where all such materials are in closed, leak-proof
containers at all times.
6) Material
handling areas for any lead-containing materials. The following areas are
exempt from the total enclosure requirements unless the areas listed also
contain operations listed in subsections (a)(1) through (5):
A) Those
areas where refined lead is melted and cast;
B) Those
areas where spent refractory brick is stored in closed containers prior to and
after crushing;
C) Those
areas where ladle repairs take place; or
D) Those
areas where lead-bearing scrap is sorted and handled, if the area is enclosed
and equipped with a capture system ducted to a control device subject to the
requirements of Section 226.140(e) during all sorting and handling activities
and if the scrap is stored in closed containers at all other times.
b) An owner
or operator of a lead emission unit subject to this Part must duct the gas
stream collected by each total enclosure to a control device that meets the
applicable requirements of Section 226.140.
c) The
total enclosure must be maintained and operated with an inward flow of air
through all natural draft openings while the lead emission unit applicable to
the operation listed in subsection (a) in the total enclosure is operating.
The average facial velocity of air flowing into the enclosure through all
natural draft openings during operation of lead emission units in each total
enclosure in any one hour period must be at least 200 fpm (3,600 m/hr) or an average
negative pressure value of 0.007 inches of water (0.013 mm Hg) must be
maintained inside the enclosure over any one hour period.
d) The
total enclosure required by subsection (a) must be maintained at any opening,
including, but not limited to, vents, windows, passages, doorways, bay doors,
and roll-ups while lead emission units in the total enclosure or enclosures are
operating, except as needed for temporary access to conduct manufacturing
operations (e.g., during load-in and load-out of materials or passage of
personnel or equipment).
e) The
total enclosure must be free of cracks, gaps, corrosion, or other deterioration
that could cause or result in dust being emitted to the atmosphere through those
openings, except that the total area of all natural draft openings must not
exceed 5 percent of the surface area of the total enclosure's walls, floor, and
ceiling.